Comparative analysis of adaptive statistical iterative reconstruction-V (ASiR-V) and non-ASiR-V performance in dose
Nieke Eka Rachmawatie1, Nurul Fatonah1, Muhammad H Firdaus1
1Department of Physics, Sepuluh Nopember Institute of Technology, Surabaya, Indonesia.
None:
Pediatric chest computed tomography (CT) requires optimization of image quality while minimizing the radiation dose, especially for low-contrast anatomical structures. This study aimed to develop and utilize novel, Various Age-size Pediatric Chest Phantoms (VAPC) models for 1-, 4-, and 7-year-old pediatric patients to systemically evaluate the effect of varying adaptive statistical iterative reconstruction-Veo (ASiR-V) levels under dose conditions consistent with American Association of Physicists in Medicine Report 246 recommendations for pediatric chest CT (as detailed in the Methods section). Phantom models were generated from datasets in the Digital Imaging and Communications in Medicine format, obtained from The Cancer Imaging Archive, and scanned using five protocols with Adaptive Statistical Iterative Reconstruction-Veo (ASiR-V) levels of 20%, 40%, 60%, and 80%. The absorbed doses in the lungs, soft tissue, spine, and heart were measured using Gafchromic LD-V1 films. The image quality was evaluated using the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and noise power spectrum. Increasing the ASiR-V percentage consistently improved image quality, with 80% ASiR-V producing significant SNR gains (e.g. 5.63-7.93, in 1 year-old), increased CNR, and 42%-61% noise reduction compared with filtered back projection. The 1 year-old phantom showed an 80.7% reduction in lung dose (2.99-0.58 mGy), and the 4 year-old phantom showed a 42.01% reduction in lung dose (3.07-1.78 mGy) at the same parameters (80% ASiR-V). In contrast, the 7 year-old phantom showed the largest gain in image fidelity. Overall, ASiR-V showed optimal performance in younger phantoms (1 year) while maintaining anatomical details and achieving improved dose efficiency in the 7 year-old phantom, supporting its effectiveness for low-dose pediatric chest-CT imaging.
More Related Videos
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies III: Computed Tomography