Related Experiment Video
Updated: Jun 24, 2026

Mapping the Binding Site of an Aptamer on ATP Using MicroScale Thermophoresis
Published on: January 7, 2017
A Molecular "Thermometer" for Measuring Effective Non-Local Exchange
Stefan Grimme1, Marcel Müller1,2,3, Thomas Froitzheim1
1Mulliken Center for Theoretical Chemistry, Clausius-Institute for Physical and Theoretical Chemistry, University of Bonn, Bonn, Germany.
Abstract:
Non-local exchange (NLX) is a key ingredient for accurate density functional calculations, but its effective strength is often hard to quantify beyond simple global hybrids. To this end, we introduce a molecular probe based on the isomerization of hexaethynylbenzene to carbo-benzene, a reaction with exceptional sensitivity to exchange effects. Using the isomerization energy, we define a simple relative measure, , that gauges the effective NLX of a method on a scale ranging from 0 for the local density approximation to 100 for Hartree-Fock. Across a broad set of density functional approximations, closely tracks the formal Hartree-Fock exchange content of global hybrids, while revealing that most common GGAs, meta-GGAs, and global hybrids still provide too little effective exchange. Several range-separated hybrid, double hybrid, and some local hybrid functionals perform much better and closely approach the near-basis-set-limit coupled-cluster reference value of . The values of various semiempirical quantum mechanical and machine-learned interatomic potential methods indicate that they empirically account for NLX effects to a varying degree. Thus, the proposed reaction serves as a compact thermochemical benchmark for assessing and developing methods that aim to reliably describe NLX.
More Related Videos
11:44Spin Saturation Transfer Difference NMR (SSTD NMR): A New Tool to Obtain Kinetic Parameters of Chemical Exchange Processes
Published on: November 12, 2016
09:15Measuring Biomolecular DSC Profiles with Thermolabile Ligands to Rapidly Characterize Folding and Binding Interactions
Published on: November 21, 2017
Related Concept Videos
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...
Thermodynamic Potentials
Thermometers and Temperature Scales
As many physical properties depend on temperature, the variety of thermometers is...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...