Related Experiment Video
Updated: Jun 26, 2026

Paired Cisterna Magna Nanoinjection and Laser Speckle Contrast Imaging Assay to Study Cerebral Blood Flow Regulation In Vivo
Published on: July 8, 2025
Different injection speeds produce distinct temporal dynamics of optic nerve sheath diameter increase during caudal
Wenshuang Yang1, Ding Han1, Siyuan Xie1
1Anesthesiology, Capital Center for Children's Health, Capital Medical University, Capital Institute of Pediatrics, Beijing, China.
Background:
Caudal block increases optic nerve sheath diameter (ONSD), but its temporal dynamics vary considerably across centers. Injection speed is one of the unstandardized factors in caudal block, and whether it influences ONSD dynamics remains unclear.
Purpose:
We therefore evaluated the effect of injection speed on ONSD changes during caudal block in children.
Design:
A prospective, randomized, observer-blinded trial.
Methods:
This study enrolled children aged 1-3 years undergoing perineal surgery. Participants received a caudal block with 0.2% ropivacaine (0.5 mL/kg) at either 1 mL/s (high-speed) or 0.1 mL/s (low-speed). ONSD was measured at baseline, immediately after injection, and at 10, 20 and 40 min time points. The primary outcome was ONSD change over time. Linear mixed-effects models were used for analysis.
Results:
Eighty children were analyzed. At T2, ONSD was significantly higher in the high-speed group (4.73 ± 0.43 mm) than in the low-speed group (4.52 ± 0.35 mm, P = 0.027); at T3, ONSD was significantly higher in the low-speed group (4.73 ± 0.57 mm) than in the high-speed group (4.49 ± 0.42 mm, P = 0.010). Both groups showed significant ONSD increases from T1 onward (P < 0.05), without return to baseline by T4. A significant time-by-group interaction (P < 0.001) indicated different temporal patterns. The maximum ONSD value did not differ between groups (4.8 mm, p = 0.537). No significant differences were observed in mean arterial pressure, heart rate, or end-tidal carbon dioxide at any time point (P > 0.05). No adverse events occurred.
Conclusion:
At an injection volume of 0.5 mL/kg, both speeds were well tolerated. Faster injection advances the observed ONSD peak; slower injection produces a more gradual rise and is therefore recommended for routine practice.
Clinical Trial Registration:
https://www.chictr.org.cn, identifier ChiCTR2200057459.
More Related Videos
07:13An Alternative and Validated Injection Method for Accessing the Subretinal Space via a Transcleral Posterior Approach
Published on: December 7, 2016
10:10Ultrahigh Resolution Mouse Optical Coherence Tomography to Aid Intraocular Injection in Retinal Gene Therapy Research
Published on: November 2, 2018