Quantitative Assessment of Endoscope Tip Angulation Performance in New Endoscopes: A Cross-Sectional Quality
Saksham Kohli1, Vikram Kotwal2, Mihir Shah2
1Department of Internal MedicineJohn H Stroger Jr Hospital of Cook CountyChicagoIllinoisUnited States.
Abstract:
Background Endoscope tip angulation is a key determinant of procedural maneuverability, yet routine quantitative assessment is not standardized, and data are limited on how quickly new endoscopes fall below manufacturer-specified performance benchmarks during routine use. The aim of this study was to evaluate tip angulation performance in new, apparently functional endoscopes after a period of clinical use and to characterize the prevalence and pattern of below-tolerance findings by scope type. Methods We performed a quality improvement project to evaluate the tip angulation of newly issued endoscopes within nine months of clinical use. In phase 1, endoscopes were systematically assessed by three trained physicians using a reference chart. In phase 2, a company representative independently evaluated endoscopes using a calibrated instrument. Results In all, 32 new endoscopes (18 colonoscopes and 14 gastroscopes) were evaluated. All scopes were used for approximately 9 months. The mean procedure count for colonoscopes was 185.6 (±12.5, range 162-201) and for gastroscopes was 150.6 (±12.0, range 133-166). Totally, 5 out of 18 colonoscopes (27.8%) fell below manufacturer tolerance thresholds for maximal tip deflection in at least one direction. All 14 gastroscopes met manufacturer tolerance thresholds in all four directions. Conclusions This cross-sectional study found that a notable proportion of new colonoscopes fell below manufacturer tolerance thresholds after approximately nine months of clinical use, despite being considered apparently functional. These findings highlight the need for periodic, objective assessment of tip angulation, even in endoscopes without apparent defects. Longitudinal studies are needed to establish deterioration trajectories and inform maintenance guidelines.
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Procedures II: Colonoscopy