Respiratory Monitoring in Motion: An Overview of Wearable Methods and Algorithmic Approaches for Reliable Assessment
Michal Pecik1, Erik Vavrinsky1, Diana Vitazkova1
1Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia.
Abstract:
Advances in wearable device and sensor technologies progressively shift respiratory monitoring from the clinical setting to real-world conditions. This rapidly developing field allows for more accurate diagnostics. However, reliable monitoring during dynamic activities remains challenging due to artifacts caused by movement, postural changes, electrode drift, and variability in breathing patterns. Therefore, this review focuses on wearable methodologies capable of determining respiratory rate and potentially tidal volume during strenuous physical activities. Direct sensing approaches, including chest and abdominal belts, bioimpedance principles, and inertial sensing units, are complemented by indirect methods derived from ECG and PPG signals. Hybrid systems, which are also discussed, represent a very promising approach. Special attention is paid to signal processing, machine learning, and multimodal sensor fusion algorithms that improve robustness and reliability. By systematically analyzing hardware and software combinations, validation protocols, and current limitations, this article identifies emerging trends in adaptive respiratory monitoring. This review aims to guide the development of next-generation wearable systems.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...