Related Experiment Video
Updated: Jun 26, 2026

Surgical Bone Implantation Technique for Rat Tibia Models of Diabetes and Osteoporosis
Published on: July 5, 2024
Intraosseous Temperature Predictors During Osteotomy with Helix GM (Titanium) and Zi Compact Drill Systems
Sebastian Contreras1, Daniel Alvitez-Temoche1, Franco Mauricio1
1Faculty of Dentistry, Research, Innovation and Entrepreneurship Unit, Universidad Nacional Federico Villarreal, Lima 15088, Peru.
None:
Background: Excessive heat during implant osteotomy adversely affects bone healing and osseointegration. It is essential to carefully study the effects of drill systems, motors, and irrigation methods on intraosseous temperature. We aim to analyze the predictors of intraosseous temperature variation during osteotomy in bovine bone blocks using the Helix GM (Titanium) and Zi Compact (Zirconium) drill systems in conjunction with three different surgical motors and irrigation conditions using a linear regression model. Materials and Methods: An in vitro experimental study was conducted at the Periodontology and Oral Implantology Laboratory of the Universidad Nacional Federico Villarreal. A total of 120 bovine rib bone blocks (1.5 cm) were prepared using a standardized osteotomy protocol involving lance drills and ∅ 2 mm and ∅ 3 mm helical drills from the Zi and Helix GM compact kits (Neodent, Curitiba, Brazil). Irrigation was performed with chlorhexidine 0.12% + CPC 0.05% at ambient temperature (21 °C). Osteotomies were executed with two surgical motors (Coxo and Driller) at 1200 rpm and 35 Ncm torque. The intraosseous temperature was recorded in real time via a calibrated Fluke TiS55+ (Fluke, Everett, WA, USA) infrared thermographic camera and validated using a probe thermometer. Statistical analyses used Stata 17, applying descriptive measures, t-tests, and linear regression at 95% confidence for reliability. Results: Osteotomies without irrigation consistently resulted in slightly higher intraosseous temperatures. The Helix GM system, with the ∅ 3 mm drill and Driller motor, produced a final temperature of 29.3 °C ± 2.0. The Zi system with the lance drill and drill motor produced a maximum temperature of 32.7 °C ± 2.3. Irrigation was successful, and the elevated temperatures after irrigation were close to the surgical room temperature of 21-23 °C. Linear regression analysis showed that the drill motor produced a statistically significant decrease in temperature (-2.29 °C; 95% CI: -4.36 to -0.21; p = 0.031) while the lance drill with no additional irrigation produced a statistically significant increase in temperature (0.24 °C; 95% CI: 0.06 to 0.42; p = 0.009). Conclusions: The absence of irrigation during osteotomy significantly increased the intraosseous temperature, potentially compromising bone integrity. The use of irrigation, especially with the Driller motor, demonstrates a protective thermal effect.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...

