The Agreement of Readability and Interpretability of Fetal Heart Rate Between Mobile and Conventional
Pajaree Ruenpeng1,2, Suchaya Luewan1,2, Threebhorn Kamlungkuea1,2
1Department of Obstetrics and Gynecology, Faculty of Medicine, Chiang Mai University, Chiang Mai 50200, Thailand.
Background/Objective: Conventional cardiotocography (CTG) is an essential tool for fetal surveillance but remains inaccessible in many low-resource settings. Emerging low-cost, wireless mobile CTG systems designed for home-based use may enhance global access to fetal monitoring. Nevertheless, their concordance with conventional CTG in the interpretation of FHR patterns remains insufficiently validated. This study aimed to evaluate agreement in the readability and interpretability of FHR baseline patterns and accelerations/decelerations between mobile and conventional CTG. Methods: A prospective study was conducted in pregnant women undergoing antepartum surveillance to evaluate agreement in the interpretation of FHR tracings simultaneously obtained from mobile and conventional CTG. Each paired tracing was independently and blindly assessed by two physician reviewer groups. Results: A total of 404 women underwent simultaneous assessment with both modalities. Agreement in baseline FHR interpretation was excellent between reviewer groups and modalities (ICC > 0.95). Interpretation of accelerations and decelerations also demonstrated very good agreement (κ = 0.8-0.9), whereas agreement for FHR variability and uterine contractions was moderate. Both reviewer groups assigned slightly but significantly higher quality scores and satisfaction scores to conventional CTG compared with mobile CTG. Conclusions: Mobile CTG demonstrates excellent agreement with conventional CTG in the assessment of FHR baseline and accelerations/decelerations. However, the overall quality and user satisfaction associated with mobile CTG were slightly lower than those observed with conventional CTG. Because of its advantages, including lower cost, portability, and user-friendly design, mobile CTG may serve as a feasible alternative for antepartum surveillance in low-resource settings worldwide.
Background/Objective: Conventional cardiotocography (CTG) is an essential tool for fetal surveillance but remains inaccessible in many low-resource settings. Emerging low-cost, wireless mobile CTG systems designed for home-based use may enhance global access to fetal monitoring. Nevertheless, their concordance with conventional CTG in the interpretation of FHR patterns remains insufficiently validated. This study aimed to evaluate agreement in the readability and interpretability of FHR baseline patterns and accelerations/decelerations between mobile and conventional CTG. Methods: A prospective study was conducted in pregnant women undergoing antepartum surveillance to evaluate agreement in the interpretation of FHR tracings simultaneously obtained from mobile and conventional CTG. Each paired tracing was independently and blindly assessed by two physician reviewer groups. Results: A total of 404 women underwent simultaneous assessment with both modalities. Agreement in baseline FHR interpretation was excellent between reviewer groups and modalities (ICC > 0.95). Interpretation of accelerations and decelerations also demonstrated very good agreement (κ = 0.8-0.9), whereas agreement for FHR variability and uterine contractions was moderate. Both reviewer groups assigned slightly but significantly higher quality scores and satisfaction scores to conventional CTG compared with mobile CTG. Conclusions: Mobile CTG demonstrates excellent agreement with conventional CTG in the assessment of FHR baseline and accelerations/decelerations. However, the overall quality and user satisfaction associated with mobile CTG were slightly lower than those observed with conventional CTG. Because of its advantages, including lower cost, portability, and user-friendly design, mobile CTG may serve as a feasible alternative for antepartum surveillance in low-resource settings worldwide.
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...