Related Experiment Video
Updated: Jun 27, 2026

Finite Element Modeling for the Simulation of the Quasi-Static Compression of Corrugated Tapered Tubes
Published on: January 6, 2023
Machine Learning Prediction of the Compressive Bearing Capacity of Concrete-Filled Steel Tubes Using Random Forest
Weidi Su1,2, Yaofei Cheng1,2, Li Wei3
1Guangxi Pinglu Canal Construction Co., Ltd., Nanning 530004, China.
Abstract:
Concrete-filled steel tube (CFST) members are widely used in long-span and high-rise structures due to their high load-bearing capacity and structural efficiency. Accurate prediction of their compressive bearing capacity is essential for reliable design. In this study, a data-driven prediction model based on the Random Forest (RF) algorithm was developed using a database of 154 axial compression tests. A total of 24 parameters, including geometric dimensions, material properties, and sectional characteristics, were considered as input variables, and the model was optimized through five-fold cross-validation and hyperparameter tuning. The results indicate that the proposed model achieves high accuracy and stability, with mean predicted-to-experimental ratios of 1.002 and 0.989 for the training and testing sets, respectively, and maximum deviations within 15%. Compared with existing design codes and alternative machine learning methods, the RF model improves prediction accuracy by approximately 9% and exhibits strong generalization capability. Furthermore, independent experimental validation using nine CFST column tests confirms its reliability, with prediction errors within 5%. These findings demonstrate that the proposed model provides an effective and practical tool for predicting the compressive bearing capacity of CFST members in engineering applications.
Related Concept Videos
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Relation Between Tensile Strength and Compressive Strength of Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...
Non-destructive Tests for Concrete Strength
Measurement of Air Content in Concrete
The pressure method,...

