Published on: November 5, 2019
Comparison of Complete Blood Count Results Between K3-EDTA- and MgSO4-Anticoagulated Samples Using a DxH800 Analyzer
Aurélie Védrenne1, Florence Habarou1, Tiffany Pascreau1,2
1Biology Department, Foch Hospital, 92150 Suresnes, France.
Background/Objectives: In case of EDTA-induced pseudothrombocytopenia (PTCP), MgSO4-anticoagulated tubes are recommended for platelet counting, requiring the collection of an additional tube. The aim of this study was to analyze whether complete blood count (CBC) and differential performed on MgSO4-anticoagulated tubes were comparable to the results obtained on K3-EDTA samples, and to characterize the stability of the CBC over a 24 h period. Methods: In 355 patients (70 with a confirmed PTCP and 285 without PTCP), we compared CBC results obtained on K3-EDTA- and MgSO4-anticoagulated tubes, using DxH800 analyzers. In 33 cases, a differential was available for both anticoagulants, and for 10 patients, samples were re-analyzed 6, 12, and 24 h after the first determination. Results: In the presence or absence of clumps, white blood cell (WBC) count, hematocrit, and mean corpuscular volume (MCV) were slightly lower in MgSO4 than in K3-EDTA tubes, whereas mean corpuscular hemoglobin concentration (MCHC) was slightly higher. Mean platelet volume (MPV) was significantly lower on MgSO4- than on K3-EDTA-anticoagulated tubes. Values were highly correlated between both anticoagulants, and mean relative biases (MRBs) were below Ricos's recommendations, except for MCHC and MPV. For differential, neutrophils were significantly lower on MgSO4- in comparison to K3-EDTA-anticoagulated tubes (MRB = -2.9%, below Ricos's optimal bias). The morphology of white blood cells (WBCs) was similar on both anticoagulants. During storage at room temperature, MCV and red cell distribution width increased slightly, but the increase was more pronounced in K3-EDTA than in MgSO4 tubes. Conclusions: CBC and differentials obtained with the DxH 800 analyzer on MgSO4-anticoagulated samples are similar to those obtained with K3-EDTA, except for MPV.
Background/Objectives: In case of EDTA-induced pseudothrombocytopenia (PTCP), MgSO4-anticoagulated tubes are recommended for platelet counting, requiring the collection of an additional tube. The aim of this study was to analyze whether complete blood count (CBC) and differential performed on MgSO4-anticoagulated tubes were comparable to the results obtained on K3-EDTA samples, and to characterize the stability of the CBC over a 24 h period. Methods: In 355 patients (70 with a confirmed PTCP and 285 without PTCP), we compared CBC results obtained on K3-EDTA- and MgSO4-anticoagulated tubes, using DxH800 analyzers. In 33 cases, a differential was available for both anticoagulants, and for 10 patients, samples were re-analyzed 6, 12, and 24 h after the first determination. Results: In the presence or absence of clumps, white blood cell (WBC) count, hematocrit, and mean corpuscular volume (MCV) were slightly lower in MgSO4 than in K3-EDTA tubes, whereas mean corpuscular hemoglobin concentration (MCHC) was slightly higher. Mean platelet volume (MPV) was significantly lower on MgSO4- than on K3-EDTA-anticoagulated tubes. Values were highly correlated between both anticoagulants, and mean relative biases (MRBs) were below Ricos's recommendations, except for MCHC and MPV. For differential, neutrophils were significantly lower on MgSO4- in comparison to K3-EDTA-anticoagulated tubes (MRB = -2.9%, below Ricos's optimal bias). The morphology of white blood cells (WBCs) was similar on both anticoagulants. During storage at room temperature, MCV and red cell distribution width increased slightly, but the increase was more pronounced in K3-EDTA than in MgSO4 tubes. Conclusions: CBC and differentials obtained with the DxH 800 analyzer on MgSO4-anticoagulated samples are similar to those obtained with K3-EDTA, except for MPV.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
EDTA: Indirect and Alkalimetric Titration
Complexometric EDTA Titration Curves
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
EDTA: Auxiliary Complexing Reagents
EDTA: Chemistry and Properties