Development and Preliminary Validation of a MALDI-TOF MS Assay Using KTI as an Internal Standard for Serum M-Protein
Jin Wang1, Yiming Zhao1, Shuanglian Xie1
1Department of Hematology, Peking University First Hospital, Beijing 100032, China.
None:
Background and Objectives: Conventional assays for M-protein detection in multiple myeloma (MM), including serum immunofixation electrophoresis (sIFE) and serum free light-chain (sFLC) assays, have limitations in selected clinical settings. This pilot study aimed to develop and preliminarily validate a matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)-based workflow using Kunitz trypsin inhibitor (KTI) as an internal standard for patient-specific serum M-protein light-chain tracking, particularly in low-level post-treatment samples in which conventional assays may be negative or difficult to interpret. Materials and Methods: A total of 55 serum samples from 25 patients with MM were analyzed. Serum immunoglobulin light-chain species were enriched using mixed κ/λ affinity beads, followed by reduction, KTI-based calibration, and MALDI-TOF MS analysis. Quantitative performance was evaluated using purified IgG1 κ standards. Time-matched sIFE and sFLC ratio results were used for descriptive comparison. Results: After KTI-based calibration, patient-specific M-protein light-chain molecular masses could be consistently identified. The assay showed good linearity over the range of 0.20-10.00 μg/mL, with a calibration equation of y = 6.0228x + 0.1063 and an R2 of 0.9961. The limit of detection and limit of quantification were 0.002 μg/mL and 0.008 μg/mL, respectively. Intra-day and inter-day precision were acceptable, and recovery ranged from 96.0% to 101.2%. In selected low-level or discordant samples, including cases with therapeutic interference, polyclonal background, or non-secretory disease, MALDI-TOF MS provided exploratory complementary monitoring information. Conclusions: This KTI-calibrated MALDI-TOF MS workflow showed preliminary analytical performance within the validated low-concentration range and may serve as a complementary approach for patient-specific serum M-protein light-chain monitoring in selected clinical settings of MM. Larger independent studies are required before its clinical utility can be established.
More Related Videos
11:09An HS-MRM Assay for the Quantification of Host-cell Proteins in Protein Biopharmaceuticals by Liquid Chromatography Ion Mobility QTOF Mass Spectrometry
Published on: April 17, 2018
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
Related Concept Videos
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...