Related Experiment Video
Updated: Jun 27, 2026

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Beyond Single-Lead ECG-Derived Respiration Analysis: Use of Vectorcardiograms from the EASI-System for Breathing
Felix Maximillian Kuon1, Lucas Bohlen2,3,4, Laura Jacobsen2
1Faculty of Life Sciences, Hamburg University of Applied Sciences (HAW Hamburg), Ulmenliet 20, 21033 Hamburg, Germany.
None:
Precise respiration assessment is crucial for heart rate variability (HRV) interpretation as respiratory components-particularly respiratory sinus arrhythmia (RSA)-provide essential information on vagally mediated regulation. Conventional single-lead electrocardiogram-derived respiration (EDR) methods measure the amplitude modulation of the QRS-waveform caused by respiratory chest movements. This causes a displacement of the electrical heart axis in relation to the ECG lead axis, typically within the 2D frontal plane of the Einthoven electrode montage. Another approach is based on heartbeat acceleration and deceleration during respective inspiration and expiration causing RR interval modulation. However, interval-based methods depend on the complexity of sympathovagal factors that affect RSA. The present feasibility study accounts for the 3D rotational movement of the electrical heart axis during the respiratory cycle and avoids non-respiratory neuromodulatory confounds. The beat-to-beat cardiac rotation was extracted from Frank-XYZ coordinates reconstructed via a four-electrode EASI device. In a pilot study with data from 19 healthy adults performing acoustically paced breathing (6-18 bpm), three surrogates (RR-IntervalEDR, R-AmplitudeEDR, HeartmovementEDR) were compared using a unified Python 3.11.13 pipeline (3D VCG R-peak detection, multivariate Mahalanobis artifact correction, wavelet-based analysis) against a synthetic reference derived from the instructed breathing schedule. The results demonstrated a consistently lower estimation error and higher reference-based signal-to-noise ratio (refSNR), measuring spectral alignment with the paced-breathing trajectory for HeartmovementEDR and achieving a mean refSNR of 6.01 dB (vs. 4.62 dB for RR-IntervalEDR and 3.20 dB for R-AmplitudeEDR) and a mean absolute estimation error of 0.016 Hz (vs. 0.050 Hz and 0.032 Hz, respectively). Notably, HeartmovementEDR and R-AmplitudeEDR performance slightly improved at higher heart rates, consistent with the interpretation that higher cardiac sampling density benefits spectral resolution for chest movement-based methods, whereas RR-IntervalEDR showed no significant heart rate dependence. Furthermore, HeartmovementEDR was compared with the EDR results obtained by applying the Kubios-HRV Premium software (version 3.5.0). Kubios-EDR yielded higher precision at elevated breathing frequencies, whereas HeartmovementEDR outperformed Kubios-EDR at breathing rates below 10 bpm-a range that is particularly relevant for vagally activating slow breathing protocols or treatments. Future work should validate this method using a direct respiration measurement under spontaneous natural breathing conditions.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: