BRDF-Corrected Vicarious Calibration of FORMOSAT-5 RSI Using RadCalNet: Quantitative Assessment and Implications for
Yi-Ling Chang1,2, Kuo-En Chang2,3, Kuo-Hsien Hsu4
1Department of Space Science and Engineering, National Central University, Taoyuan City 320317, Taiwan.
None:
Accurate radiometric calibration is essential for high-resolution optical satellite sensors with limited onboard calibration capability, such as the FORMOSAT-5 (FS-5) Remote Sensing Instrument (RSI). The Radiometric Calibration Network (RadCalNet) provides standardized nadir-equivalent surface reflectance for vicarious calibration, but its direct application to off-nadir observations can introduce systematic biases over non-Lambertian surfaces. This study presents a BRDF-corrected vicarious calibration framework for the FS-5 RSI. The framework integrates RadCalNet data with an empirical BRDF lookup table built from in situ multi-angle measurements at Railroad Valley Playa, which is then propagated through 6S radiative transfer simulation. Applied to four FS-5 overpasses, BRDF correction reduced the median relative error of the calibration coefficient K0 from 13-17% to 1-4% across all five spectral bands, providing a quantitative assessment of calibration improvement. The downstream impact was evaluated over an FS-5 La Crau scene. Scene-mean top-of-atmosphere (TOA) reflectance differences across the four multispectral bands ranged from 8.62% (NIR) to 10.99% (Green). The near-infrared reflectance of vegetation (NIRv), a proxy for gross primary production, showed a scene-mean relative difference of 7.88% ± 7.32%, with localized values exceeding 20% in densely vegetated areas. These results establish quantitative calibration-accuracy requirements for sensors relying on vicarious calibration and demonstrate the operational necessity of BRDF correction for reliable TOA reflectance and vegetation product retrieval.
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Flame Photometry: Lab
IR Spectrometers