Optimized Design and Radiation Error Correction of a Naturally Ventilated Air Temperature Sensor for Atmospheric
Wei Jin1,2, Qingquan Liu1,2, Wei Dai3
1Jiangsu Key Laboratory of Meteorological Observation and Information Processing, Nanjing University of Information Science and Technology, Nanjing 210044, China.
None:
Air temperature measurements in atmospheric environmental monitoring are susceptible to radiation-induced bias under natural ventilation. This study develops a low-power naturally ventilated air temperature sensor and a correction method combining computational fluid dynamics (CFD) with machine learning. The sensor integrates a Pt100 thin-film platinum resistance probe (Heraeus Holding GmbH, Hanau, Germany), symmetric guide plates, and a dual aluminum-plate radiation shield to reduce radiative heating while improving airflow around the probe. A three-dimensional fluid-solid coupled heat-transfer model was established in ANSYS FLUENT 15.0 to optimize guide-plate spacing and inclination angle and quantify the effects of solar radiation, long-wave radiation, scattered radiation, air density, wind speed, solar elevation angle, and surface albedo on radiation error. CFD results identified a guide-plate spacing of 24 mm and an inclination angle of 45° as the preferred parameters. A multilayer perceptron (MLP) model trained with CFD-derived data was validated in field experiments using a Model 076B aspirated radiation shield (Met One Instruments, Inc., Grants Pass, OR, USA) as the reference. The model predicted radiation error with a root mean square error (RMSE) of 0.052 °C, a mean absolute error (MAE) of 0.042 °C, and a correlation coefficient of 0.92. The proposed sensor and correction method provide a low-power and easy-to-maintain approach for reducing radiation-induced bias in naturally ventilated air-temperature measurements, with potential applications in meteorological observation, air-quality monitoring, and agricultural microclimate assessment.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Absorption of Radiation
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Distance Corrections