Development of an Instrumented Glove for Palmar Pressure Assessment in Kayakers
Corentin Depontailler1,2, Gurvan Jodin1,2, Corentin Porcon1,2
1Department of Mechatronics, École Normale Supérieure de Rennes, 35170 Bruz, France.
None:
Understanding hand-paddle interaction is essential for optimizing performance and preventing injury in kayaking, yet coaches still lack objective, practical tools. We present a soft, instrumented glove that measures and dynamically maps palmar pressure throughout the stroke cycle. A matrix of piezoresistive sensors is integrated into the glove and connected to dedicated electronics housed in a waterproof enclosure. A viscoelastic model converts sensor resistance into forces, enabling time-resolved 3D mapping of contact mechanics. Data are transmitted via Bluetooth Low Energy (BLE). Experimental validation on a kayak ergometer across multiple cadences demonstrated accurate measurements (per-sensor root mean square error (RMSE) of ±2 N), clear delineation of pull and push phases, evolving pressure distribution over the motion, and a peak total right-hand force of 186 N at high cadence. Beyond feasibility, these results position the glove as a practical training aid: it supports athlete-specific load monitoring and the early detection of potentially problematic movement patterns.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)