Occupational Pelvic and Chest-Level Radiation Exposure Among Interventional Echocardiographers During Percutaneous
Priscilla Wessly1, Jeremiah Haines1, Emily Jimenez2
1Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Aurora Health Care, Milwaukee, Wisconsin, USA; Department of Cardiovascular Medicine, Atrium Health Wake Forest Baptist Medical Center, Winston-Salem, North Carolina, USA.
Background:
Rapid expansion of transcatheter structural heart interventions has increased occupational radiation exposure for interventional echocardiographers (IEs).
Objectives:
The authors aimed to quantify real-time underlead pelvic and chest-level radiation exposure to IEs during left atrial appendage occlusion (LAAO), transcatheter mitral valve intervention (TMVI), and transcatheter tricuspid valve intervention (TTVI); estimate implications for fetal safety; and identify independent predictors of higher chest dose.
Methods:
This prospective, single-center study quantified radiation exposure during 118 LAAO, 59 TMVI, and 53 TTVI procedures from February 2025 to February 2026. Multivariable linear regression on log-transformed chest-level dose identified independent predictors. Comparisons used Kruskal-Wallis, Mann-Whitney U, and Spearman tests.
Results:
Pelvic dose was 0 μSv in 98.7% of cases; estimated dose for full pregnancy was ∼2.3 μSv, well below the recommended limit. Median raw chest-level exposure was 9.0 μSv (IQR: 3.2-21.0) for LAAO, 18.0 μSv (7.5-43.5) for TMVI, and 36.0 μSv (16-116) for TTVI (P < 0.001). IEs received 10- to 50-fold higher doses than sonographers (P < 0.001). Independent predictors of higher chest-level dose were higher log(dose-area product) (1.57; 95% CI: 1.29-1.91), head-of-bed positioning (2.17; 95% CI: 1.06-4.43), TMVI (2.27; 95% CI: 1.44-3.58), and TTVI (2.70; 95% CI: 1.35-5.40) vs LAAO, and half-shield-only use (3.78; 95% CI: 1.51-9.44) (all P ≤ 0.035).
Conclusions:
The near absence of detectable under-lead pelvic radiation with standard lead apparel and shielding provides strong reassurance regarding reproductive safety. IEs sustain higher chest-level radiation exposure during TMVI and TTVI than LAAO. Head-of-bed positioning and half-shield-only use are key modifiable drivers, underscoring the need for standardized full-shielding protocols and positional awareness.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT