Related Experiment Video
Updated: Jun 28, 2026

Automated Hospital Room Disinfection Utilizing a Novel Aerosolized Hydrogen Peroxide Microdroplet Disbursing Technology
Published on: February 24, 2026
Systematic review of microorganism disinfection performance by chemical and ultraviolet light water treatment methods
Emma Wells1, Teal Bullick1, Gouthami Rao2
1University of Colorado Boulder, Boulder, CO, 80303, USA.
Abstract:
Safe drinking water is critical for public health, yet microbial contamination remains a significant global challenge. We conducted a systematic review to update World Health Organization guidance on water disinfection technologies by synthesizing peer-reviewed literature from 1997 to 2021 on the performance of free chlorine, chlorine dioxide, ozone, and ultraviolet (UV) light against bacteria, viruses, and protozoa. Following PRISMA guidelines, we analyzed log10 reduction values (LRVs) and contact times (Ct) or fluence (for UV) from laboratory and field studies. We included studies from multiple databases and expert-recommended studies. Results show mean Cts for 2 LRV of non-opportunistic bacteria as 6.0 (free chlorine), 0.4 (chlorine dioxide), and 1.2 (ozone) mg/L*min, and a mean UV fluence of 8.2 mJ/cm² (all bacteria). Viruses required lower Cts, except for UV-resistant adenoviruses, while protozoa required higher Cts or fluences. Opportunistic bacteria required significantly higher Cts than non-opportunistic bacteria for free chlorine and chlorine dioxide. Temperature and pH effects were inconsistent, highlighting data variability and gaps in field studies. These findings support global guidance on water treatment and may be used alongside other context-specific data to understand the roles these technologies play in reducing waterborne exposures. We recommend standardized reporting from performance studies to enable straightforward synthesis of evidence.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Chemical Agents for Microbial Control
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Antimicrobial Effectiveness
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...

