Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models00:57

Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models

Physiological pharmacokinetic models, often called flow-limited or perfusion models, typically assume a swift drug distribution between tissue and venous blood, creating a rapid drug equilibrium. This premise is based on the idea that drug diffusion is extremely fast, and the cell membrane presents no barrier to drug permeation. In this scenario, where no drug binding occurs, the drug concentration in the tissue equals that of the venous blood leaving the tissue. This greatly simplifies the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Standardized Reporting of Cardiac Magnetic Resonance Examinations in Children With Cardiac Diseases and Adults With Congenital Heart Disease: A Scientific Statement From the Association for European Pediatric and Congenital Cardiology (AEPC) and the International Society for Magnetic Resonance in Medicine (ISMRM).

Journal of magnetic resonance imaging : JMRI·2026
Same author

Cardiovascular risk factors and carotid plaque components in a multi-ethnic cohort using 3 Tesla MRI: the HELIUS study.

European radiology·2026
Same author

Corrigendum to "4D Flow cardiovascular magnetic resonance consensus statement: 2023 update" [Journal of Cardiovascular Magnetic Resonance 25 (2023) 40].

Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance·2026
Same author

Physics-informed graph neural networks for flow field estimation in carotid arteries.

Medical image analysis·2026
Same author

Simultaneous Volumetric T1 and T2 Mapping With Blood- and Fat-Suppression in Abdominal Aortic Aneurysms.

Magnetic resonance in medicine·2026
Same author

Automated identification, hemodynamic visualisation and quantification of abdominal aortic aneurysms with 4D flow magnetic resonance imaging.

Quantitative imaging in medicine and surgery·2026

Related Experiment Video

Updated: Jun 28, 2026

Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
06:56

Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation

Published on: January 7, 2021

Parameter estimation in blood flow models from highly undersampled k-space magnetic resonance imaging data.

Miriam Löcke1, Pim van Ooij2, Cristóbal Bertoglio3

  • 1Bernoulli Institute, University of Groningen, Groningen, The Netherlands.

Biomechanics and Modeling in Mechanobiology
|June 27, 2026
PubMed
Summary

This study introduces a new method for faster 4D Flow Magnetic Resonance Imaging (MRI) by directly using undersampled data. This approach improves the accuracy of cardiovascular blood flow models compared to current techniques.

Keywords:
4D flow MRIBlood flowsInverse problemsKalman filter

More Related Videos

Blood Flow Imaging with Ultrafast Doppler
05:57

Blood Flow Imaging with Ultrafast Doppler

Published on: October 14, 2020

Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
12:29

Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling

Published on: May 30, 2011

Related Experiment Videos

Last Updated: Jun 28, 2026

Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
06:56

Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation

Published on: January 7, 2021

Blood Flow Imaging with Ultrafast Doppler
05:57

Blood Flow Imaging with Ultrafast Doppler

Published on: October 14, 2020

Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
12:29

Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling

Published on: May 30, 2011

Area of Science:

  • Medical Imaging
  • Biomedical Engineering
  • Computational Fluid Dynamics

Background:

  • 4D Flow Magnetic Resonance Imaging (MRI) is crucial for cardiovascular inverse problems but suffers from long scan times.
  • Undersampled k-space acquisition in 4D Flow MRI necessitates assumptions for image reconstruction, leading to inaccuracies.
  • The optimal k-space sampling pattern for 4D Flow MRI is often unclear.

Purpose of the Study:

  • To develop a parameter estimation framework that directly utilizes highly undersampled 4D Flow MRI k-space data.
  • To assess the accuracy of this framework for estimating boundary-condition parameters in cardiovascular models.
  • To compare the performance of different k-space sampling strategies.

Main Methods:

  • A parameter estimation framework was developed to directly process undersampled k-space measurements.
  • The numerical solution was implemented using a Reduced-Order Unscented Kalman Filter.
  • The framework was evaluated on a synthetic aortic blood flow model and validated with real MRI data from a mechanical phantom.

Main Results:

  • The proposed framework achieved more accurate boundary-condition parameter estimates than compressed-sensing based reconstructions.
  • The study identified how estimation accuracy is influenced by various k-space sampling patterns.
  • Substantially higher accuracy was demonstrated compared to inverse problems relying on compressed-sensing reconstructed velocity fields.

Conclusions:

  • Directly using undersampled k-space data with a Reduced-Order Unscented Kalman Filter offers a more accurate approach for cardiovascular parameter estimation from 4D Flow MRI.
  • This method mitigates inaccuracies associated with traditional compressed-sensing reconstructions.
  • The findings provide guidance on selecting optimal sampling strategies for improved 4D Flow MRI analysis.