Objective:
Non-invasive monitoring of the jugular venous pulse (JVP) supports heart-failure management, but neck photoplethysmography (PPG) suffers from source ambiguity, in which arterial pulsations contaminate the venous waveform. We present a dual-channel wearable framework that automatically separates jugular venous from arterial waveforms.
Methods:
The pipeline pairs a derivative-enhanced dynamic time warping (deDTW) algorithm with a stability-adjusted, distance-based feature-ranking scheme. deDTW quantifies the morphological and timing distance between candidate beats using a signal-quality-adaptive weighting of amplitude and derivative information. From dual-channel neck recordings of 15 volunteers we extracted 73 candidate features and trained a $k$-nearest-neighbor classifier under leave-one-subject-out (LOSO) cross-validation.
Results:
Optimization selected 28 features at $k=19$, yielding a classification accuracy of 98.65%. When combined with a nearest-neighbor distance-ratio rejection rule ($\tau = 1.005$), the system reached 99.82% sensitivity for arterial beats and a 98.73% F1-score for JVP detection, and rejected 93.88% of out-of-distribution ambiguous beats while retaining 99.74% precision for valid JVP signals.
Conclusion:
The algorithm resolves venous-arterial source ambiguity, addressing a key limitation of wearable JVP analysis.
Significance:
By acting as an automated source-verification gate, the method reduces inter-observer variability and supports continuous, non-invasive JVP monitoring for remote cardiovascular assessment. Validation here is in a healthy cohort; evaluation in patients with cardiovascular disease is the subject of future work.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring pulse
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation