A pump-free gravity-driven microfluidic chip for rapid RPA-LFS-based detection of Magnaporthe oryzae AvrPi9 gene
Yu Ting Wu1, Chatchawan Jantasuriyarat2, Jyh Jian Chen3
1Department of Biomechatronics Engineering, National Pingtung University of Science and Technology, 1, Shuefu Road, Neipu, Pingtung, 91201, Taiwan.
None:
We present a pump-free, gravity-assisted microfluidic lab-on-a-chip platform for the rapid detection of the rice blast pathogen Magnaporthe oryzae by targeting the AvrPi9 gene. The system integrates precise thermal control, programmable fluidic sequencing, and lateral-flow readout, enabling low-power diagnostics without complex instrumentation. Temperature regulation is achieved using a LinkIt 7697 development board, coupled with a proportional-integral-derivative (PID) controller, to drive a Peltier element. This maintains a stable reaction environment at 39 ± 0.5 °C for recombinase polymerase amplification (RPA). The microfluidic chip (65 mm × 34 mm × 5 mm) is fabricated via laser cutting and hot pressing, with the reaction chamber validated for spatial temperature uniformity through infrared thermal imaging. To enhance operational reliability in field settings, the platform utilizes a manual pin-actuated puncture mechanism to initiate fluidic transport. After a 5-minute isothermal amplification, the physical piercing of a sealing membrane opens strategic air vents, inducing a capillary-driven flow and pressure imbalance that facilitates the pump-free transport of 30 µL of RPA products into the lateral flow strip (LFS). This deterministic mechanical gating replaces complex actuators, ensuring a 100% success rate for vent opening. Visual results appear within 2 min, with a total assay time of approximately 15 min, achieving a detection limit of 10 pg/µL for AvrPi9. The system demonstrates high specificity, with no cross-reactivity to non-target pathogens, including Bipolaris oryzae, Sarocladium oryzae, and Ephelis sp., owing to strategic primer mismatches. This robust, pin-actuated, valve-free system highlights the potential for reliable, low-power, field-deployable nucleic acid diagnostics in point-of-care settings. While this study serves primarily as a hardware engineering proof-of-concept focusing on pump-free fluidic transportation, it establishes a foundational architecture for decentralized molecular diagnostics. Future translational development will focus on integrating raw matrix sample preparation to bypass the current limitation of requiring purified nucleic acid inputs.