Related Experiment Video
Updated: Jul 2, 2026

State of the Art Cranial Ultrasound Imaging in Neonates
Published on: February 2, 2015
Bubbles in the barely born-contrast-enhanced ultrasound in neonates: a single-center experience
Alexandros Rahn1, Thomas Müller2, Diane Renz3
1Department of Pediatric Pulmonology, Allergology and Neonatology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany. rahn.alexandros@mh-hannover.de.
Abstract:
To assess clinical value, safety, and applicability of contrast-enhanced ultrasound (CEUS) in neonates, focusing on bedside use in intensive care. This retrospective single-center study included 23 neonates undergoing intravenous CEUS between 2010 and 2024, including seven preterm infants. The liver (n = 18) was the most frequently examined organ, followed by kidneys (n = 2), brain (n = 2), and adrenals (n = 1). Findings were compared with MRI (n = 10), CT (n = 3), or biopsy (n = 8), when available. In nine cases, CEUS findings were consistent with clinical course and treatment response only, without an independent reference standard. Among the 14 cases with available reference diagnostics, CEUS established the diagnosis first in ten (71.4%); histological confirmation was available in eight cases, with concordance in five (62.5%). 13 examinations (56.5%) were performed for bedside problem-solving in the neonatal intensive care unit, and no adverse events were observed.
Conclusion:
CEUS provided clinically relevant diagnostic information in neonates, including preterm and critically ill infants and was well tolerated. CEUS was particularly valuable in hepatic vascular tumors, where it could provide a definite diagnosis, enabled hemodynamic assessment, supported treatment decisions, and aided identification of potentially life-threatening complications. Bedside use enabled timely diagnosis without sedation, intubation, or patient transport, thereby supporting minimal handling. In selected cases, CEUS may reduce the need for cross-sectional imaging. Despite off-label use, our findings suggest a beneficial role for CEUS in neonatal imaging, predominantly for hepatic indications.
What Is Known:
• Contrast-enhanced ultrasound (CEUS) is a radiation-free, bedside-compatible imaging technique with an established safety profile in pediatric patients. • Neonatal CEUS experience is limited to small case series, predominantly reporting cerebral applications.
What Is New:
• CEUS was feasible and well tolerated in neonates including preterm infants, with no adverse events in 23 examinations. • CEUS yielded clinically relevant diagnostic information across a range of indications, primarily hepatic, encompassing both focal lesions and perfusion assessment, supporting clinical decision-making in neonatal care.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies II: Ultrasonography
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...