Related Experiment Video
Updated: Jul 2, 2026

Novel Techniques for Observing Structural Dynamics of Photoresponsive Liquid Crystals
Published on: May 29, 2018
An optimized ultrafast transient absorption experiment from the visible to the near-infrared with the B matrix
Maximilian M Horn1, Kaila M Yallum2, Natalie Banerji1
1Department of Chemistry, Biochemistry, and Pharmaceutical Sciences, University of Bern, Freiestrasse 3, CH-3012 Bern, Switzerland.
Abstract:
We present a transient absorption (TA) setup with a broadband white-light from 600 to 1700 nm without a detection gap. This TA setup differs from typical TA implementations in two distinct details. First, instead of seeding the 800 nm fundamental laser beam directly into the white-light generation (WLG) crystal, we pump our yttrium aluminum garnet WLG crystal with the 2080 nm idler of a home-built two-pass optical parametric amplifier pumped at 800 nm. Second, we implement the B matrix referencing scheme introduced by Feng et al. to suppress the white-light fluctuations down to the shot-noise limit of our detector. As such, our implementation of the B matrix leads to a reduction of the root mean square of about an order of magnitude in the 1200-1700 nm regime compared to the ratiometric referencing approach. Furthermore, we suppress baseline oscillations frequently encountered in TA by mitigating the effects of negative pixel correlation. To allow widespread implementation of the referencing scheme in the scientific community, we provide an introduction to the B matrix focusing specifically on data processing. The B matrix referencing scheme is easy to implement and is employed directly during data acquisition, thus maintaining similar alignment and measurement times compared to typical TA implementations. Finally, we show that the noise reduction provided by the B matrix referencing scheme allows for WLG schemes that would otherwise fluctuate too much to provide high-quality data in a reasonable amount of time, enabling the construction of more specialized TA experiments.
Related Concept Videos
UV–Vis Spectroscopy: Molecular Electronic Transitions
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
IR Absorption Frequency: Hybridization
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that stretch at a...
UV–Vis Spectrometers

