Related Experiment Video
Updated: Jul 3, 2026

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Comparison of Carotid Artery Surface Temperature versus Axillary Surface Temperature in Children Undergoing Surgeries
Sonal Sagar Khatavkar1, Ashish Erry
1Department of Anaesthesiology, Dr. D. Y. Patil Medical College, Hospital and Research Centre, Dr. D. Y. Patil Vidyapeeth, Pimpri, Pune 411018, Maharashtra, India.
Insights
Carotid artery surface temperature accurately reflects core body temperature in children during surgery. Axillary temperature monitoring is unreliable for pediatric patients, showing significant underestimation of core temperature.
Area of Science:
- Pediatric Anesthesiology
- Perioperative Thermoregulation
- Medical Device Accuracy
Background:
- Pediatric patients are vulnerable to intraoperative hypothermia due to physiological factors.
- Accurate core body temperature monitoring is crucial during pediatric anesthesia.
Purpose of the Study:
- To compare the accuracy of noninvasive carotid artery and axillary surface temperatures against nasopharyngeal core temperature in children.
- Evaluate noninvasive thermometry methods for pediatric surgical patients.
Main Methods:
- Prospective, randomized, double-blind observational study.
- 130 pediatric patients (1-6 years) undergoing elective surgery >2h.
- Comparison of nasopharyngeal, carotid surface, and axillary temperatures.
Main Results:
- Carotid artery surface temperature showed strong correlation and minimal bias (0.10°C) compared to nasopharyngeal temperature.
- Axillary temperature significantly underestimated core temperature by 1.0°C-1.3°C (P < 0.0001).
- Hemodynamic parameters were comparable between groups.
Conclusions:
- Carotid artery surface thermometry is a reliable, noninvasive alternative for monitoring pediatric core body temperature.
- Axillary temperature monitoring is insufficiently accurate for pediatric intraoperative use.
Context:
Pediatric patients are exceptionally vulnerable to intraoperative hypothermia due to their anatomical characteristics and the thermoregulatory impairment caused by anesthetic agents. Accurate core temperature monitoring is critical.
Aims:
The aim of this study was to compare the accuracy of noninvasive carotid artery surface and axillary surface temperatures against standard nasopharyngeal core temperature in children under general anesthesia.
Settings And Design:
A prospective, randomized, double-blind observational study conducted at a tertiary care hospital.
Subjects And Methods:
A total of 130 children (American Society of Anesthesiologists Physical Status I-II, aged 1-6 years) undergoing elective surgeries lasting over 2 h were randomized into two equal cohorts (n = 65 each). Postintubation, Group A had nasopharyngeal and axillary probes placed, while Group B received nasopharyngeal and carotid surface probes. Temperature and hemodynamic parameters were recorded at 15-min intervals for 120 min.
Statistical Analysis Used:
The independent Student's t-test, Pearson's correlation, and Bland-Altman analysis were utilized (SPSS v26.0).
Results:
Carotid artery surface temperature strongly correlated with nasopharyngeal temperature, displaying a minimal mean bias of 0.10°C (P > 0.05). Conversely, axillary temperature significantly underestimated core temperature by 1.0°C to 1.3°C throughout the intraoperative period (P < 0.0001). Hemodynamic parameters remained comparable across both the groups.
Conclusions:
Carotid artery surface thermometry is a highly reliable and noninvasive alternative to nasopharyngeal core temperature monitoring, whereas axillary temperature lacks sufficient accuracy.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...