Intra-SVC re-entrant atrial tachycardia successfully treated with a circular multi-electrode array pulsed-field
Takeru Ikenaga1, Masatsugu Nozoe1, Hiroshi Mannoji1
1Division of Cardiology, Cardiovascular and Aortic Center, Saiseikai Fukuoka General Hospital, 1-3-46 Tenjin, Chuo-ku, Fukuoka 810-0001, Japan.
Intra-SVC re-entrant atrial tachycardia (AT) is rare. Pulsed-field ablation (PFA) effectively isolated the superior vena cava (SVC) in a patient with recurrent AT, demonstrating PFA
Area of Science:
- Cardiology
- Electrophysiology
- Medical Devices
Background:
- Atrial fibrillation (AF) can originate from the superior vena cava (SVC), but intra-SVC re-entrant atrial tachycardia (AT) is exceptionally uncommon.
- Recurrent AT after pulmonary vein (PV) isolation prompted a second ablation procedure.