Investigating the Potential of Singly Curved Thin Piezoelectric Transducers for Energy Harvesting and Structural Health Monitoring
Published on: November 14, 2025
Pulse sensor for cardiovascular health monitoring based on self-poled piezo-tribo hybrid composites
Soham Kumar1, Jyotika Nanda2, Sam K Jacob1
1Department of Physics, SRM University - AP Andhra Pradesh 522 240 India pranab.m@srmap.edu.in.
Abstract:
Wearable devices, such as a pulse sensor, can be useful for real-time monitoring of cardiovascular health. Continuous and systematic monitoring of cardiovascular parameters can predict conditions such as coronary artery disease, heart failure, cardiac arrest, etc. However, most commercial wearable sensors are typically limited to macroscopic metrics such as heart rate and SpO2. This work introduces a sensitive piezoelectric-triboelectric hybrid composite-based pulse sensor that provides insight into an individual's cardiovascular health by measuring heart rate variability (HRV) metrics, including heart rate, P-P intervals (the time between successive heartbeats), and RMSSD (the root mean square of successive differences between intervals). The high sensitivity of the sensor is rooted in a dual strategy: first, the piezoceramic BaTi0.94Sn0.06O3 (BST6) is engineered at a morphotropic phase boundary, yielding an excellent piezoelectric coefficient of . Second, the device employs a layer-by-layer configuration incorporating a self-poling PDMS-MWCNT interfacial layer sandwiched between the PDMS-BST6 hybrid composite layers. This layered architecture facilitates self-poling by enhancing charge collection at the PDMS-MWCNT layer while suppressing recombination at the PDMS-BST6 hybrid composite layer. Further, Short-Time Fourier Transform (STFT) and Dynamic Time Warping (DTW) analyses of the recorded pulse wave suggest device stability over 100 days and evaluate heart condition. This study opens the scope for an IoT-enabled wearable system for long-term, real-time cardiovascular health monitoring and assessment.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...