Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Finite element analysis of high-rise prefabricated shear walls with discontinuous rebars
Zhiqi Li1,2, Jun Peng3,4, Hairen Wang1,2
1School of Architectural Engineering, Yulin University, Yulin, 719000, China.
Abstract:
The seismic performance of vertical reinforcement discontinuous splice prefabricated shear walls (SGBL prefabricated shear walls) in high-rise buildings is investigated in this study. The failure mechanisms, load-bearing capacity, ductility, and energy dissipation characteristics of these walls are clarified, with particular attention given to the influence of the shear-span ratio and axial compression ratio. A refined model was established using ABAQUS finite element software, and simulations were conducted on individual SGBL wall panels under various shear-span ratios (achieved by adjusting story heights) and axial compression ratios (0.1, 0.3, 0.5). The results demonstrate that the load-bearing capacity of the wall panels increases significantly with the axial compression ratio (Specimens with shear-span ratios of 1.25, 1.5, and 1.75 exhibited increases of 76.8%, 88%, and 82%, respectively). In contrast, ductility and energy dissipation capacity are reduced. When an axial ratio of 0.5 and a shear-span ratio of 1.25 were applied, interlaced diagonal cracks were observed in specimen SW1-0.5. Therefore, the inclusion of inclined reinforcement is recommended in practice to prevent premature brittle failures. Under a constant axial compression ratio, it was found that the load-bearing capacity decreases as the shear-span ratio increases, whereas ductility and energy dissipation capacity are enhanced. Specimen SW3-0.1, characterized by a low axial compression ratio and a large shear-span ratio, exhibited the optimum energy dissipation capacity and ductility. During the simulation, no vertical cracks were observed at the joint interface between the precast panels and the cast-in-situ components, confirming that the structure exhibits excellent integrity and compatibility.
Related Concept Videos
Shear on the Horizontal Face of a Beam Element
Shearing Stresses in a Beam: Problem Solving
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Design Example: Distributing Reinforcements in Concrete Sections
Method of Sections: Problem Solving II
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal loadings...