Related Experiment Video
Updated: Jul 5, 2026

Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
Impact of Higher Versus Lower Blood Pressure Targets on Pulmonary Vascular Hemodynamics During Intensive Care After
Shira K Hendin1, Rasmus P Beske1, Jesper Kjaergaard1,2
1Department of Cardiology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.
Background:
Hemodynamic management after out-of-hospital cardiac arrest (OHCA) is critical, yet the impact of vasopressor-driven mean arterial pressure (MAP) targets on pulmonary circulation and right ventricular (RV) function remains unclear.
Methods:
In this substudy of the randomized, double-blinded BOX trial, comatose OHCA survivors were allocated to low (63 mmHg) or high (77 mmHg) MAP targets. Pulmonary artery catheters (PAC) were used for serial hemodynamic assessment for 48 h after Intensive Care Unit admission. The primary endpoint was calculated pulmonary vascular resistance (PVR), secondary endpoints included pulmonary capillary wedge pressure (PCWP), pulmonary artery pulsatility index (PAPi), and RV cardiac power output (RV-CPO)-a measurement of RV pumping function.
Results:
Among 730 included patients (median time randomization to PAC insertion 1.3 h), mPAP was consistently higher in the high-MAP group (mean difference 1.11-1.71 mmHg, 95% CI range 0.12-2.59). Calculated PVR was transiently lower in the high-MAP group during the first 24 h (mean difference -0.16 to -0.30, 95% CI range -0.31 to 0.11), before converging between groups. RV-CPO was lower in the low-MAP group throughout the observation period (mean difference 0.01-0.04 W [95% range 0.00-0.07], with the largest difference at 48 h. PCWP decreased in both groups but was significantly lower in the low-MAP group during the first 12 h (mean difference 1.06-1.40 mmHg, 95% CI range 0.25-2.38).
Conclusions:
In comatose OHCA survivors, targeting a higher MAP increased pulmonary artery pressures, PCWP, RV-CPO, heart rate, and cardiac output. The proportionally greater increase in cardiac output over pulmonary artery pressures resulted in a decreased calculated PVR.
Trial Registration:
ClinicalTrials.gov identifier: NCT03141099.
Editorial Comment:
In this secondary analysis of a subgroup in the BOX out of hospital cardiac arrest treatment trial for oxygen level targets, blood pressure treatment target levels, higher or lower were analyzed, including central circulatory outcomes, using a pulmonary artery catheter. The higher blood pressure target group had accompanying higher pulmonary artery pressures and cardiac output, with initially a small reduction in calculated pulmonary vascular resistance.
Related Concept Videos
Measurement of Blood Pressure
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the diastolic...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Factors affecting Blood pressure
Physiological Factors:
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...