Related Experiment Video
Updated: Jul 6, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Semiautomated magnetic resonance imaging-based breast density measurement from routine sequences: comparison with
Y Takatsu1, M Shimizu2, T Nakamura3
1Graduate School of Medical Sciences, Fujita Health University, 1-98, Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan; Department of Molecular Imaging, Clinical Collaboration Unit, School of Medical Sciences, Fujita Health University, 1-98, Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan; Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan.
Aim:
High breast density increases breast cancer risk and decreases mammographic sensitivity, yet prior magnetic resonance imaging (MRI)-based density assessments have relied on specialized sequences or vendor-dependent software. This study aimed to evaluate a semiautomated workflow for MRI-based breast density measurement using routinely acquired MRI sequences and compare its diagnostic performance and concordance with visual and software-based mammographic classifications.
Materials And Methods:
In this single-center retrospective study, we analyzed 113 women (mean age: 60.8 ± 13.6 years) who underwent both breast MRI and mammography. The contralateral, normal breast was evaluated. MRI was performed using a 3.0-T scanner with a 3D T1-weighted gradient-echo sequence. Breast and fibroglandular tissues were segmented using a deep learning-assisted automated method with manual correction. Statistical analyses included correlation analysis, Bland-Altman analysis, and receiver operating characteristic (ROC) analysis.
Results:
MRI-based breast density showed a strong correlation with mammographic density (r = 0.781, P < 0.001), although MRI values were on average 27.7% lower. The area under the ROC curve for detecting high-density breasts was 0.869 for MRI and 0.799 for mammography (P = 0.085).
Conclusions:
Semiautomated MRI-based breast density assessment using routine MRI sequences allowed for quantitative evaluation of breast composition without using ionizing radiation. MRI-based density measurements exhibited classification performance comparable to mammographic assessment. These findings support the potential utility of MRI for quantitative breast density evaluation, although further validation and workflow standardization are required before broader clinical application.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI