Related Experiment Video
Updated: Jul 7, 2026

Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
Published on: October 7, 2015
Data-driven estimation of core body temperature during physical activity under heat exposure: A systematic review and
Yuanzhe Zhao1, Weihao Li2, Jeroen Hm Bergmann1,3
1Department of Engineering Science, University of Oxford, Oxford, UK.
Abstract:
Accurate, real-time estimation of core body temperature (CBT) during physical activity is essential for monitoring heat strain and mitigating the risk of heat-related illness under hot environmental conditions. Although numerous data-driven algorithms using wearable sensors have been proposed, their practical reliability remains unclear due to substantial methodological heterogeneity and the absence of standardized evaluation. This study combined a systematic review with a standardized quantitative benchmark. A total of 38 studies employing non-invasive inputs for CBT estimation were identified. Of these, 14 eligible models, including Kalman filter-based methods, statistical models, and machine-learning approaches, were re-implemented and evaluated under identical preprocessing and evaluation settings using two independent datasets: Dataset 1 (treadmill walking, ) and Dataset 2 (cycling, ). The benchmark revealed notable differences between originally reported performance and reproduced performance under standardized conditions. For the widely used heart-rate-based extended Kalman filter, the root mean square error (RMSE) increased from typically reported values of 0.21-0.41 C to 0.41 C on Dataset 1 and 0.66 C on Dataset 2. Incorporating skin temperature improved tracking accuracy in some configurations, but performance gains were highly dependent on measurement site and dataset. Sensitivity for detecting elevated CBT ( 38.0 C) varied markedly across methods, particularly for the cycling protocol. In conclusion, no single CBT estimation approach consistently outperformed others across all settings. Heart-rate-only models provided a stable baseline under limited sensing conditions, whereas multimodal approaches offered conditional benefits in more controlled scenarios. This work establishes a standardized benchmark framework to support fair comparison, method selection, and future development of (wearable) CBT estimation technologies.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Body Temperature
The average body temperature is approximately 37°C (98.6°F) and typically ranges from 36.1–37.2°C (97–99°F), remaining relatively stable...
Body Temperature
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...