Related Experiment Video For Diagnostic method
Updated: Jul 7, 2026

Functional Characterization of Endogenously Expressed Human RYR1 Variants
Published on: June 9, 2021
Primary myotubes as an alternative to the calcium induced calcium release test in diagnosing malignant hyperthermia
Sachiko Otsuki1, Keiko Mukaida2, Hirotsugu Miyoshi3
1Department of Anesthesiology and Critical Care, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan.
Background:
Malignant hyperthermia (MH) is caused by the dysregulation of calcium (Ca2+) in skeletal muscle cells. In this study, we evaluated the accuracy of a method for diagnosing susceptibility to MH using myotubes as an alternative to Ca2+-induced Ca2+ release rate (CICR) test.
Methods:
In this retrospective study, we retrospectively analyzed Ca2⁺ kinetics data obtained using fura-2/AM from myotubes that had been cultured from remnant muscle fibers of 98 patients who had previously undergone CICR testing for MH susceptibility in Japan. The 50% effective concentrations (EC50) of caffeine and 4-chloro-m-cresol (4-CmC) were calculated from the concentration response curves. The previously calculated cut-off values (caffeine: 3.62 mM, 4-CmC: 197 μM) were used to diagnose susceptibility to MH. The diagnostic accuracy of myotubes was compared with that of the CICR test. Statistical significance was tested using the Mann-Whitney U test.
Results:
The CICR test identified 76 patients as CICR-Positive and 22 patients as CICR-Negative. The EC50 for caffeine was 2.9 (2.4-3.3) and 5.0 (4.5-5.5) mM in the CICR-Positive and CICR-Negative groups, respectively (p < 0.0001). The EC50 of 4-CmC was 130 (116-148) and 249 (226-289) μM in the CICR-Positive and CICR-Negative groups, respectively (p < 0.0001). The sensitivity for caffeine for myotubes was 98.7% (95%CI 92.9-99.9). The specificity for caffeine was 100% (95%CI 85.1-100.0). The sensitivity and specificity for 4-CmC were 100% (95%CI 95.2-100.0) and 100% (84.5-100.0), respectively.
Conclusions:
Myotubes responses to caffeine and 4-CmC can be regarded as a viable alternative to the conventional CICR test; however, further validation is needed before this test supersedes the CICR.
More Related Videos
13:41Magnetic Resonance-Guided High Intensity Focused Ultrasound Generated Hyperthermia: A Feasible Treatment Method in a Murine Rhabdomyosarcoma Model
Published on: January 13, 2023
10:45Isolation of Human Myoblasts, Assessment of Myogenic Differentiation, and Store-operated Calcium Entry Measurement