Related Experiment Video
Updated: Jul 9, 2026

Sample Preparation in Quartz Crystal Microbalance Measurements of Protein Adsorption and Polymer Mechanics
Published on: January 22, 2020
Crossover frequency as a model-independent viscoelastic constant for soft tissue biomechanics
Laura Ruhland1, Jakob Schattenfroh2, Jing Guo2
1Institute of Applied Mechanics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Egerlandstr. 5, 91058, Erlangen, Germany.
None:
Magnetic resonance elastography (MRE) and related elastography techniques are emerging as quantitative diagnostic tools for assessing tissue microstructure and pathology. To determine descriptive parameters of the tissues' properties, a frequency-dependent viscoelastic material model is required, which is calibrated to the measured response in a parameter identification process. However, the selection of this model and the fitting strategy is challenging, since it may influence the identified viscoelastic parameters notably. Here, we address this limitation by proposing the crossover frequency (fc, defined as the frequency at which storage and loss moduli intersect G'(fc)=G''(fc)) as a model-independent viscoelastic constant for soft tissues. Fresh porcine specimens of the corona radiata, the putamen, the thalamus, and the liver were investigated using tabletop MRE and the frequency-dependent viscoelasticity was characterized with a fractional Kelvin-Voigt model. By validating the crossover frequency against the viscoelastic parameters, we demonstrated that the crossover frequency accurately reflects the viscoelastic behavior, independent of the material model or the fitting strategy. Across all samples, fc distinguished brain regions and separated brain from liver tissue by median frequencies of 85Hz (95% CI: 69-269Hz) in the corona radiata, 423Hz (95% CI: 316-575Hz) in the putamen, 426Hz (95% CI: 302-601Hz) in the thalamus and 1174Hz (95% CI: 1074-1300Hz) in the liver (p<0.001). These results suggest that crossover frequencies capture distinct viscoelastic fingerprints without requiring viscoelastic model selection. The crossover frequency may therefore serve as a practical, model-independent biomaterial constant to improve comparability of viscoelastic measurements across elastography studies.
More Related Videos
11:28A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Related Concept Videos
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Elastic Strain Energy for Shearing Stresses
Viscosity of Fluid
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Generalized Hooke's Law