Potential of quantitative X-ray imaging from photon-counting CT: A novel analysis based on effective atomic number
Takashi Asahara1, Rina Nishigami2, Natsumi Kimoto3
1Department of Radiological Technology, Faculty of Health Sciences, Okayama University, Okayama, Japan.
Background:
Conventional CT assessment of lung lesions is based mainly on morphological features. CT values represent relative X-ray attenuation that does not directly reflect tissue composition and/or physical density. Quantitative imaging using photon-counting CT (PC-CT) has the potential to provide quantitative parameters, such as effective atomic number (Zeff) and effective physical density (ρeff).
Purpose:
The purpose is to develop and demonstrate the potential of an algorithm that generates both the Zeff and ρeff images, derived directly from virtual monoenergetic images (VMIs) acquired with a clinical PC-CT system.
Methods:
The ρeff image was generated by fitting a database of mass attenuation coefficients (μ/ρ) to the measured linear attenuation coefficients (μ), which were obtained from two VMIs at 70 and 100 keV. As an effective material, Zeff information was also determined and fed back into the ρeff calculation. An in-house low-density phantom was scanned for quantitative evaluation of ρeff. In addition, to demonstrate the applicability of our procedure to actual clinical imaging, representative chest PC-CT images from patients were analyzed.
Results:
In experiments using low-density phantoms, the CT values did not necessarily correlate with Zeff values, but they showed a very good correlation with the ρeff values. The ρeff values calculated using our procedure correlated well with the correct values of ρ. A relative root mean square error of ρeff calculation was 5.5%. Furthermore, we found that in pulmonary diagnosis, image contrast information from ρeff makes it easier to identify and distinguish lesions compared to that from Zeff.
Conclusions:
The proposed procedure directly generated Zeff and ρeff images from PC-CT data and enabled quantitative interpretation of CT value in terms of elemental composition and physical density. In this study, the feasibility of generating Zeff and ρeff images was demonstrated.
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Determination of Crystal Structures
Electron Behavior
Electrons Orbit the Nucleus
Electrons are found in specific locations outside of the nucleus. The shell in which an electron resides indicates the general energy level of the electron: those closer to the nucleus have less energy,...