Related Experiment Video
Updated: Jul 9, 2026

Ultrasonography of the Adult Male Urinary Tract for Urinary Functional Testing
Published on: August 14, 2019
Wearable Ultrasound Devices for Continuous Bladder Monitoring: Emerging Utility and Current Limitations in
Sehwan Kim1,2, Aram Kim3,4
1Department of Biomedical Engineering, School of Medicine, Dankook University, Cheonan, Korea.
Wearable ultrasound devices show promise for monitoring bladder fullness in children with functional voiding dysfunction. However, current technology is not yet accurate enough for neurogenic bladder patients, requiring further validation for clinical use.
Area of Science:
- Neurourology
- Medical Ultrasound Technology
- Digital Health
Background:
- Continuous bladder filling monitoring is vital for managing neurogenic lower urinary tract dysfunction and enabling clean intermittent catheterization.
- Wearable ultrasound devices offer a novel approach to bladder monitoring, distinct from traditional bladder scanners.
- First-generation wearable devices primarily track fullness trends and provide alerts, lacking precise volume measurement capabilities.
Purpose of the Study:
- To review current wearable ultrasound technologies for bladder monitoring in neurourology.
- To assess the clinical performance and regulatory status of these devices.
- To identify evidence gaps and future directions for wearable bladder monitors.
Main Methods:
- A narrative review of studies identified through searches in PubMed, Embase, IEEE Xplore, and Google Scholar.
- Analysis of clinical data, focusing on pediatric populations and neurogenic bladder conditions.
- Examination of device regulatory classifications and technological advancements.
Main Results:
- Wearable devices like SENS-U show high sensitivity (85%-90%) for detecting bladder fullness thresholds in pediatric functional voiding dysfunction.
- Performance in neurogenic bladder populations is concerning, with low accuracy (46%) and high false positives (13%) reported for devices like DFree.
- Limited prospective validation studies exist for adult neurogenic bladder populations; regulatory approvals vary significantly.
Conclusions:
- Current wearable bladder monitors are suitable only for pediatric functional voiding dysfunction under medical supervision.
- Routine clinical use in neurogenic bladder populations is not recommended due to insufficient diagnostic accuracy.
- Future advancements, particularly B-mode deep learning devices, may overcome current limitations and improve clinical utility.
Related Concept Videos
Imaging Studies II: Ultrasonography
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Urodynamic Studies: Uroflowmetry