Related Experiment Video
Updated: Jul 9, 2026

Biaxial Mechanical Characterizations of Atrioventricular Heart Valves
Published on: April 9, 2019
From biaxial tests to cardiac digital twins: a morphomechanics agenda for passive myocardium
Fulufhelo Nemavhola1, Thanyani Pandelani1,2
1Department of Mechanical Engineering, Faculty of Engineering and the Built Environment, Durban, South Africa.
Abstract:
Passive myocardial mechanics shape ventricular filling, ventricular-ventricular interaction, and the mechanical environment experienced by cardiac cells. Yet many cardiac finite-element and digital-twin models still estimate passive material behaviour mainly from chamber-level pressure-volume or imaging data, which can reproduce global observables while leaving tissue-scale parameters poorly identifiable. In this Perspective, we define morphomechanics as an operational model-data integration framework in which myocardial structure, tissue-scale stress-strain behaviour, and organ-level function jointly determine constitutive-law selection, parameter priors, and calibration constraints for cardiac digital twins. The term is used to fill a practical gap between conventional multiscale modelling and digital-twin calibration: it specifies how experimentally measured tissue mechanics and quantitative microstructure should constrain organ-scale model parameters. We review insights from planar biaxial testing of ventricular myocardium, including porcine, rat, and sheep datasets that reveal nonlinear elasticity, directional anisotropy, and regional heterogeneity. We then examine how passive myocardial properties are currently estimated in digital-twin workflows and identify where tissue-level evidence remains underused. Finally, we propose an actionable roadmap in which biaxial data inform constitutive-law selection and probabilistic parameter priors; diffusion imaging and histology define local material axes and structural anisotropy; and inverse finite-element calibration incorporates tissue-derived constraints through Bayesian priors, regularization penalties, or staged calibration. By explicitly linking myocardial microstructure, tissue-scale mechanics, and organ-scale simulation, a morphomechanics-driven approach could improve physiological fidelity, parameter identifiability, and translational confidence in cardiac digital twins.
More Related Videos
09:15Displacement Analysis of Myocardial Mechanical Deformation (DIAMOND) Reveals Segmental Heterogeneity of Cardiac Function in Embryonic Zebrafish
Published on: February 6, 2020
09:59Biaxial Basal Tone and Passive Testing of the Murine Reproductive System Using a Pressure Myograph
Published on: August 13, 2019