Related Experiment Video
Updated: Jul 10, 2026

Capturing Dynamic Finger Gesturing with High-resolution Surface Electromyography and Computer Vision
Published on: March 28, 2025
A robust biometric system using wrist and dorsal vein images for person authentication
1Department of Electronics and Communication Engineering, Dr. Mahalingam College of Engineering and Technology, Pollachi, Tamil Nadu, India. guru101090@gmail.com.
Abstract:
Vein biometric authentication systems are crucial in military and forensic applications, where security remains a primary concern. The potential compromise of stored biometric data within databases poses a significant security risk. To address this problem, a hybrid biometric template protection method utilizing chaotic encryption and innovative perturbation algorithms has been introduced. The vein images are subjected to preprocessing, and vein line patterns are extracted utilizing line-tracking methods in conjunction with curvature analysis. The extracted features are integrated employing a feature fusion technique and preserved through an innovative perturbation-based encryption method. The encrypted images are subjected to thorough security evaluations, encompassing correlation analysis, pixel change rate (NPCR) testing, histogram examination, and entropy assessment. The proposed multimodal system exhibits an accuracy of 99.85% and an Equal Error Rate of 0.017 when utilizing the ResNet deep learning mode.
Related Concept Videos
Veins of Upper Limbs
The deep venous system is primarily composed of the ulnar and radial veins. The ulnar vein, which drains the fingers through the superficial palmar venous arches, and the radial vein, which serves the palms via the deep palmar...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...