Related Experiment Video
Updated: Jul 10, 2026

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Transcatheter edge-to-edge repair with DragonFlyTM system and 'stepless self-locking' strategy in a patient with
Xinping Lin1,2,3,4, Yuming Wang1,2,3,4, Boren Tan1,2,3,4
1Department of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Jiefang Road 88, Hangzhou 310000, China.
Background:
Transcatheter edge-to-edge repair (TEER) has emerged as an alternative treatment for severe mitral regurgitation (MR). However, complex anatomical features of mitral valve pose significant technical and procedural challenges for TEER. In patients whose effective regurgitation reduction requires multiple clips, a small mitral valve area (MVA) limits TEER by increasing the risk of post-procedural elevated transvalvular gradients and iatrogenic stenosis.
Case Summary:
A 90-year-old man presented with progressive tightness of breath that remained refractory to drug-based medical therapy. Echocardiography revealed severe mixed mitral regurgitation characterized by C1 segment prolapse and atrial functional mitral regurgitation with a small MVA of 4.09 cm2. Given his advanced age and prohibitive surgical risk (Society of Thoracic Surgeons [STS] score for repair: 10.49%), the multidisciplinary Heart Team elected to perform TEER using the DragonFlyTM system. The procedure was successfully performed under transoesophageal echocardiographic (TEE) guidance with the sequential implantation of two clips. The second clip utilized a 'Stepless self-locking' strategy to carefully balance the reduction of regurgitation against the transmitral pressure gradient elevation. Regurgitation was reduced from grade 4 + to 1 + with a final mean gradient of 4 mmHg and no evidence of significant mitral stenosis. The patient experienced a marked improvement in functional status during the follow-up period.
Discussion:
This case highlights the importance of individualized anatomical assessment and tailored device selection in managing patients with MR and complex, challenging structure. Precise clip sizing and stepwise deployment strategies can successfully balance MR reduction while preserving MVA. Such tailored approaches are essential to prevent iatrogenic complications and optimize clinical outcomes in high-risk populations.