Dual-energy x-ray imaging for AI-based lung tumor localization using foundation models: a phantom study
Nawal Alqethami1, Wentao Xie1, Tom Julius Blöcker2
1Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Garching b. München, Germany.
AI foundation models combined with dual-energy X-ray imaging significantly improve tumor localization accuracy, especially in challenging areas with bone overlap. This advanced technique reduces missed tumor fractions compared to high-energy imaging alone.
Area of Science:
- Medical Imaging
- Artificial Intelligence
- Radiology
Background:
- Dual-energy (DE) X-ray imaging offers potential for improved tissue contrast.
- AI foundation models are increasingly used for medical image analysis.
- Accurate tumor tracking is crucial for effective treatment planning.
Purpose of the Study:
- To assess AI-based tumor tracking performance using DE X-ray versus high-energy (HE) X-ray.
- To evaluate the impact of DE imaging parameters on tumor localization.
- To compare AI model accuracy with manual ground truth segmentation.
Main Methods:
- DE planar imaging with fast kVp-switching was performed on a phantom.
- Weighted logarithmic subtraction generated soft-tissue-enhanced DE images.
- An AI foundation model was used for frame-by-frame tumor localization and compared to ground truth.
Main Results:
- Optimal weighting factors for bone suppression ranged from 0.57 to 0.79.
- Increased tube current improved DE contrast-to-noise ratio (CNR).
- AI model achieved high localization accuracy (Dice > 0.9, HD95 < 2-3 mm) on both DE and HE images.
- DE imaging significantly reduced the missed tumor fraction compared to HE images (e.g., <15% for DE vs. 50-55% for HE with 80/120 kVp).
Conclusions:
- Integrating DE imaging with AI foundation models enhances tumor localization accuracy.
- This approach is particularly beneficial in anatomically challenging regions with tumor-bone overlap.
- DE imaging shows superior performance in minimizing missed tumor areas compared to HE imaging.
More Related Videos
05:11Construction of An Orthotopic Xenograft Model of Non-Small Cell Lung Cancer Mimicking Disease Progression and Predicting Drug Activities
Published on: May 10, 2024
08:32Using Computer-based Image Analysis to Improve Quantification of Lung Metastasis in the 4T1 Breast Cancer Model
Published on: October 2, 2020
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
X-ray Imaging