The CathPilot: Usability and Feasibility Evaluation in Simulated-Use Endovascular Interventions
Sina Mohammadmahdi Keshavarz1,2,3, James Zhou4,5, Alykhan Sewani4,5
1Department of Biomedical Engineering, Toronto Metropolitan University, Toronto, Canada. mkeshavarz@torontomu.ca.
Abstract:
Endovascular treatment of complex peripheral artery disease and chronic total occlusions remains a significant challenge. This is largely due to limited distal control of devices used and reliance on proximal manipulation with conventional catheters. To bridge this gap, we previously developed the CathPilot, a modular steerable catheter that integrates a self-expanding nitinol frame for local anchoring with a real-time graphical user interface that provides cross-sectional tip position feedback alongside fluoroscopy. This study compares the CathPilot with conventional non-steerable catheters in a simulated-use, within-subjects design. Eight interventional clinicians each performed three lesion-crossing attempts per device in a silicone phantom model of human vasculature. Silicone lesions were positioned in the left superficial femoral artery. Objective endpoints included lesion-crossing success, procedure time, fluoroscopy time, and radiation dose. Subjective assessments included the System Usability Scale (SUS) for perceived usability and NASA Task Load Index (NASA-TLX) for operator workload. Combining objective performance with human-factors instruments enabled a comprehensive assessment of the CathPilot's procedural usability against conventional catheters. CathPilot achieved a 92% lesion-crossing success rate with approximately 3 × improvement compared to conventional catheters. Clinician-level and lesion-level procedure times, and fluoroscopy times were significantly lower when using the CathPilot. Similarly, the NASA-TLX workload rating was significantly lower for CathPilot. Under simulated-use conditions, these findings indicate the potential of the CathPilot system to address endovascular revascularization challenges and demonstrate the added value of precise distal tip control, tracking, and support.
More Related Videos
06:18Pioneering Patient-Specific Approaches for Precision Surgery Using Imaging and Virtual Reality
Published on: April 5, 2024
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023