Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Impact of PEEP Valve Type on Respiratory Effort During Free-Flow Helmet CPAP
Sergio Lassola1, Eleonora Balzani2, Marco Casarotti3
1Drs. Lassola, De Rosa, Bellani, and Mr. Re are affiliated with Department of Anesthesia and Intensive Care 1, Santa Chiara Hospital, APSS, Trento, Italy.
Background:
Helmet continuous positive airway pressure is widely used to treat acute hypoxemic respiratory failure. However, circuit components such as PEEP valve type may influence airway pressure stability and the work of breathing. We investigated whether V˙-dependent (V˙D) PEEP valves generate additional inspiratory effort compared with V˙-independent (V˙I) PEEP valves and evaluated the potential buffering effect of a reservoir bag.
Methods:
In this crossover physiological study, 30 healthy volunteers underwent 3 helmet CPAP settings in randomized order: V˙D PEEP valve, V˙I PEEP valve, and V˙-dependent valve combined with a 25-L reservoir bag V˙D-reservoir. Each setting was tested at fresh gas flows of 80 and 120 L/min. Airway pressure swings (ΔPaw) and nasal pressure swings (ΔPnose), used as a surrogate of inspiratory effort, were continuously recorded.
Results:
V˙D PEEP valves generated significantly larger ΔPaw compared with V˙I PEEP valves. These airway pressure swings were associated with greater inspiratory effort. Differences in ΔPnose were evident at 80 L/min, where inspiratory effort was higher with the V˙D PEEP valve, but disappeared at 120 L/min despite persistent differences in ΔPaw. The addition of a reservoir bag partially attenuated inspiratory effort compared with the V˙D PEEP valve alone.
Conclusions:
During helmet CPAP in healthy volunteers, PEEP valve type significantly influenced airway pressure stability and inspiratory effort. V˙I PEEP valves provided more stable airway pressure, whereas V˙D PEEP valves imposed additional inspiratory effort. Increasing fresh gas flow or adding a reservoir bag partially mitigated this effect, highlighting the importance of circuit configuration in optimizing helmet CPAP performance.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...