Related Experiment Videos
Flexible Gravitational-Wave Parameter Estimation with Transformers
Annalena Kofler1,2, Maximilian Dax1,3,4, Stephen R Green5
1Max Planck Institute for Intelligent Systems, Max-Planck-Ring 4, 72076 Tübingen, Germany.
Abstract:
Gravitational-wave data analysis relies on accurate and efficient methods to extract physical information from noisy detector signals, yet the increasing rate and complexity of observations represent a growing challenge. Deep learning provides a powerful alternative to traditional inference, but existing neural models typically lack the flexibility to handle variations in data analysis settings. Such variations accommodate imperfect observations or are required for specialized tests, and could include changes in detector configurations, overall frequency ranges, or localized cuts. We introduce a flexible transformer-based architecture paired with a training strategy that enables adaptation to diverse analysis settings at inference time. Applied to parameter estimation, we demonstrate that a single flexible model-called dingo-t1-can (i) analyze 48 binary black holes from the third LIGO-Virgo-KAGRA Observing Run under a wide range of analysis configurations, (ii) enable systematic studies of how detector and frequency configurations impact inferred posteriors, and (iii) perform inspiral-merger-ringdown consistency tests probing general relativity. dingo-t1 also improves median sample efficiency on real events from a baseline of 1.4% to 4.2%. Our approach thus demonstrates flexible and scalable inference with a principled framework for handling missing or incomplete data-key capabilities for current and next-generation observatories.
Related Concept Videos
Transformers with Off-Nominal Turns Ratios
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the copper windings...
Estimation of the Physical Quantities
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
The Ideal Transformer
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's tangential component...