Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Fuzzy robust model predictive fault tolerant control in wind turbine based on ST-SMO and PMIO
Yixin Zhou1,2, Jia Liu3,4, Yixiao Gao1,2
1College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou, 310023, China.
Abstract:
Conventional wind turbine maintenance relies on post-failure diagnosis, yet sustained degraded operation remains critical. This paper proposes a fault-tolerant model predictive control (MPC) framework with switching between a super-twisting sliding mode observer (ST-SMO) and a proportional multiple integral (PMI) dual observer system. In the observation layer, the PMI observer estimates unmeasured states and various faults, while the ST-SMO specifically compensates for high-order pitch angle faults. A Takagi-Sugeno (T-S) fuzzy logic based on the ν-gap metric coordinates the two observers. Adaptive penalty terms in the MPC layer compensate deviations via a linear parameter-varying model. Multi-scenario case studies validate the framework under load-range transitions and simultaneous multi-fault conditions. Compared with single-observer FTC methods and conventional MPC, the proposed framework improves maximum power tracking accuracy by 18% under sensor faults, suppresses drivetrain torsional torque fluctuation by 50% under cross-load switching, and reduces tower bending moment damage equivalent load (DEL) by 19.63% under multi-fault conditions. It innovatively integrates dual observers with T-S fuzzy logic and hard-soft combined LPV switching, achieving synergistic optimization of fault tolerance, fatigue load mitigation, and active power maximization for megawatt-class wind turbines under multi-fault coupling and cross-load transitions.
Related Concept Videos
Wind Turbine Machine Models
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Turbine-Governor Control
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Load-frequency control
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal and...