Related Experiment Video
Updated: Jul 12, 2026

Applicability Analysis of Assessment Methods for Morphological Parameters of Corroded Steel Bars
Published on: November 1, 2018
Performance evaluation of corroded reinforced concrete columns strengthened with FRCM under cyclic loading and
Benyamin Rezaei1, M Reza Esfahani2
1Department of Civil Engineering, Ferdowsi University of Mashhad, Mashhad, Iran.
Abstract:
This study investigates the performance of corroded reinforced concrete (RC) columns strengthened with Fabric Reinforced Cementitious Matrix (FRCM) composites. Seven column-foundation specimens were tested under cyclic lateral loading to evaluate their behavior. The main experimental variables included the corrosion process (before and after strengthening) and the adopted strengthening method. Some of the corroded specimens were re-exposed to a corrosive environment after strengthening to estimate the process of subsequent corrosion. The strengthening was carried out using a carbon-based FRCM (C-FRCM) system, both independently and in combination with embedded Glass Fiber Reinforced Polymer (GFRP) bars (hybrid method). The experimental results were compared with the design provisions of ACI 549.4R code. The aims of this study are as follows, evaluate the performance and load carrying capacity of corroded columns, identify their failure mechanisms, assess ductility factor, energy dissipation capacity and examine the influence of strengthening on the rate of re-corrosion process.The results revealed that corrosion significantly reduced the load carrying capacity of the columns. Corrosion was found to be non-uniform along both longitudinal and transverse reinforcement bars. It led to brittle failure and a considerable decrease in energy absorption. Moreover, the hybrid strengthening system exhibited a notable improvement in structural performance, particularly in the corroded specimens. Enhancing the load carrying capacity by 54%, the energy dissipation capacity by 155% and ductility factor increased 89% compared with the control specimen. Comparison between experimental results and ACI 549.4R code predictions indicated that the code provisions are conservative. Furthermore, the proposed strengthening method reduced the corrosion rate by approximately 16%.
More Related Videos
Related Concept Videos
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating within the...
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Fatigue Strength of Concrete
Design of Columns under an Eccentric Load
Non-destructive Tests for Concrete Strength
Effects of Creep