Related Experiment Video
Updated: Jul 12, 2026

Three-Dimensional Reconstruction for the Whole Lung with Early Multiple Pulmonary Nodules
Published on: October 13, 2023
Exploring the diagnostic performance of low-dose CT for colorectal cancer assessment: feasibility of artificial
Kexin Niu1, Tiantian Wang2, Sihua Zhong2
1Department of Radiology, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Background:
Contrast-enhanced long-range abdominal computed tomography (CT) plays a crucial role in the diagnosis and staging of colorectal cancer (CRC) yet may involve excessive radiation exposure, especially for patients requiring multiple examinations. This raises the need to reduce radiation dose while maintaining image quality. Given the potential of a novel artificial intelligence iterative reconstruction (AIIR) algorithm to improve image quality in low-dose (LD) CT, this study aimed to investigate the feasibility of applying AIIR to LD abdominal CT for CRC diagnosis.
Methods:
In this prospective study, 203 patients with pathology-confirmed CRC underwent abdominal CT, including a routine-dose (RD) scan (120 kVp, 200 mAs) followed by a LD scan (120 kVp, 20 mAs) at the portal venous phase (PVP). RD images were reconstructed with hybrid iterative reconstruction (HIR, RD-HIR) and AIIR (RD-AIIR), whereas LD images were reconstructed with AIIR (LD-AIIR). Diagnostic performance for assessing visceral peritoneal invasion (VPI) and regional lymph node metastasis (RLNM) was characterized using receiver operating characteristic (ROC) analysis. Qualitative image quality was rated using a five-point scale, and tumor contrast-to-noise ratio (CNR) was measured.
Results:
The mean effective dose (ED) of LD scan was 90.3% lower than that of RD scan (1.5±0.2 vs. 14.9±2.4 mSv). RD-AIIR achieved significantly higher area under the curve (AUC) and accuracy for diagnosing VPI (0.89 and 91.13%, respectively) and RLNM (0.72 and 71.92%, respectively) compared to the other reconstructions (all P<0.05). LD-AIIR showed comparable AUC and accuracy to RD-HIR for VPI (0.81 vs. 0.80 and 82.96% vs. 78.33%, respectively; both P>0.05), but demonstrated inferior performance for RLNM (0.65 vs. 0.68 and 66.51% vs. 68.47%, respectively; P<0.05). AIIR significantly improved tumor CNR (P<0.05) and the qualitative image quality was comparable between LD-AIIR and RD-HIR (P>0.05).
Conclusions:
AIIR offers superior image quality compared to HIR. AIIR allows up to 90.3% dose reduction for reliable VPI assessment in CRC while maintaining comparable image quality to that of RD-HIR on abdominal CT.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT