Related Experiment Video
Updated: Jul 13, 2026

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Intra-vendor inter-scanner agreement of negative-HU measurements on fast kV-switching dual-energy CT virtual
Norimi Nishiyama1, Takanori Masuda2, Junnichi Nakagawa1
1Department of Radiological Technology, Okayama Saiseikai General Hospital, 2-25, Kokutai-cho, Kita-ku, Okayama-shi, 700-8511, Okayama, Japan.
Abstract:
The purpose of this study was to evaluate inter-scanner agreement and the dose-related stability of negative CT-number measurements on dual-energy CT virtual monoenergetic images under low-, mid-, and high-dose conditions. A custom phantom (sawdust, salad oil, cutting-fluid dilutions 100%-3%, and water) was scanned on two CT systems (Revolution CT and Discovery CT750 HD). DECT VMI (40-140 keV) was acquired at three CTDIvol-defined dose levels with five repeats per condition; CT numbers were measured using standardized central ROIs. Negative-HU materials increased monotonically with increasing keV on both scanners. At 70 keV, inter-scanner bias (ΔHU = Revolution - 750HD) increased as HU became more negative (r = 0.840), with an overall mean bias of - 3.57 HU and 95% limits of agreement of - 16.90 to 9.75 HU. The largest discrepancies were for sawdust (- 18.70 to - 20.09 HU). Water reference behavior differed by scanner and dose (Mean(|HU|) across 40-140 keV: 0.223 HU for Revolution vs. 2.464 HU for 750HD at low dose; 750HD remained offset at mid-high dose (2.319-2.508 HU). Dose stability at 70 keV was generally high, but 750HD showed low-dose deviations for 20% and 30% (ranges 12.13 and 12.27 HU) that diminished at mid-high dose. VMI shows predictable energy-dependent behavior for negative-HU materials, but inter-scanner bias increases for strongly negative values and low-dose conditions, and water-reference behavior can influence stability; scanner-aware interpretation and phantom-based harmonization are warranted for quantitative evaluation in the negative HU range.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

