Related Experiment Video
Updated: Jul 27, 2026

Athymic Rat Model for Evaluation of Engineered Anterior Cruciate Ligament Grafts
Published on: March 26, 2015
Treatment of Failed Patella ORIF With Novel Patella Tension Band Plate and Suture Construct: A Case Report
Hrayr Basmajian1, Cailan L Feingold2, Eric H Lin2
1Department of Orthopaedic Surgery, Premier Orthopaedic and Trauma Specialists, Pomona, California, USA.
Abstract:
Hardware failure and malunion are feared complications of open reduction and internal fixation (ORIF) of patella fractures and require revision ORIF. Given the higher complication and reoperation rates associated with revision ORIF of the patella, these procedures can be difficult. This case report presents a 51-year-old female who experienced early hardware failure and malunion of a patellar fracture after primary ORIF with tension band wiring (TBW). A revision ORIF was performed using a novel plate and suture construct that allows for the simultaneous management of the osseous and soft tissue components of the extensor mechanism.