Diagnostic Test Analysis of Intraoperative Direct Sonication in Detecting Periprosthetic Joint Infection: A

Shunsuke Kondo1,2, Norio Yamamoto2,3, Akihiro Saitsu2,4,5

  • 1Department of Medicine, John A. Burns School of Medicine, Honolulu, USA.

Cureus
|July 13, 2026
PubMed

Insights

Intraoperative direct sonication shows promise for detecting periprosthetic joint infection (PJI) by disrupting biofilms. This method achieved 88.7% sensitivity and 83.1% specificity in a meta-analysis, though more research is needed.

Area of Science:

  • Orthopedic Surgery
  • Infectious Diseases
  • Diagnostic Microbiology

Background:

  • Periprosthetic joint infection (PJI) is a significant complication following arthroplasty.
  • Current diagnostic methods for PJI can be limited by biofilm interference.
  • Intraoperative direct sonication is a novel technique to enhance pathogen detection.

Purpose of the Study:

  • To systematically review and meta-analyze the diagnostic accuracy of intraoperative direct sonication for suspected PJI.
  • To evaluate the effectiveness of sonication in disrupting bacterial biofilms on explanted components and tissues.

Main Methods:

  • A systematic literature search was conducted across multiple databases (CENTRAL, MEDLINE, Embase) and trial registries.
  • Six studies were included, with four unique datasets analyzed; two studies (n=479) using MSIS 2011 criteria were pooled for meta-analysis.
  • Hierarchical models were used to synthesize sensitivity and specificity, with risk of bias assessed using QUADAS-2.

Main Results:

  • The pooled analysis of two studies demonstrated a summary sensitivity of 88.7% (95% CI, 82.9-92.7) and specificity of 83.1% (95% CI, 73.5-89.7).
  • The risk of bias was generally low, with one study having unclear patient selection criteria.
  • The search identified 1,910 records plus 124 from other sources, with six studies meeting inclusion criteria.

Conclusions:

  • Intraoperative direct sonication exhibits promising diagnostic performance for identifying PJI.
  • The current evidence base is limited to two studies using the MSIS reference standard.
  • Larger, multicenter studies with consistent reference standards are required to confirm accuracy and establish the role of sonication in PJI diagnostics.