Related Experiment Video
Updated: Jul 14, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Synergistic integration of μ-SPE and ammoniated adduct-based MRM for sensitive UPLC-MS/MS quantification of PEG1000:
Xinyue Zhou1,2, Sufei Duan2, Yuye Lou2
1Central Hospital of Dalian University of Technology, Dalian University of Technology, Dalian, Liaoning, 116023, P.R. China.
Abstract:
A sensitive UPLC-MS/MS method was developed and validated for quantifying polyethylene glycol 1000 (PEG1000) in zebrafish tissues, featuring a systematic comparison of two MS acquisition strategies. Through comprehensive optimization, the ammonium adduct [M+NH4]+ of the representative 18-EO oligomer (m/z 828.5) was selected as the precursor ion, achieving approximately fourfold higher signal intensity than [M+H]+. Critically, the conventional high declustering potential in-source CID approach monitoring fragment ions was outperformed by the optimized MRM method monitoring the intact ammoniated precursor, which demonstrated 2.7-fold signal enhancement and superior selectivity. The integration of micro-solid-phase extraction (μ-SPE) further improved method performance, yielding 1.5-fold signal gain and markedly reduced matrix effects compared to conventional protein precipitation. The fully validated method exhibited excellent linearity (0.5-50 μg/mL, r > 0.995), accuracy, precision, and stability. Application to zebrafish tissue distribution studies revealed pronounced organ-specific accumulation following aqueous exposure to 200 μg/mL PEG1000, with highest concentrations in intestine tissue exhibiting a time-dependent increase, followed by muscle, while muscle maintained consistently low levels. This analytical platform, synergistically combining μ-SPE cleanup and ammoniated adduct-based MRM, offers superior sensitivity over in-source CID approaches and provides a practical framework for polymer bioanalysis, yielding critical insights into the in vivo fate of PEG-based compounds. The key novelties of this work are the following: (i) the first systematic comparison between ammoniated adduct MRM and high-DP in-source CID for PEG1000 quantification; (ii) the introduction of μ-SPE for sample preparation in zebrafish tissues, achieving 1.5-fold signal enhancement; and (iii) the successful application of this platform to reveal organ-specific accumulation patterns of PEG1000.
More Related Videos
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
09:24Automated Sample Multiplexing by using Combined Precursor Isotopic Labeling and Isobaric Tagging (cPILOT)
Published on: December 18, 2020