Inferior Rectus Myositis After Orbital Fracture Repair With the Medpor® Implant in a 38-Year-Old Male Patient

Thomas Ting Hei Tsang1, Fatema Aljufairi1,2, Jake U Sebastian3

  • 1Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, HKG.

Cureus
|July 14, 2026
PubMed

Insights

A rare case of inferior rectus myositis occurred after orbital fracture repair using a Medpor® implant. Surgical removal of the implant resolved the patient's symptoms, highlighting potential immune responses to orbital implants.

Area of Science:

  • Ophthalmology
  • Reconstructive Surgery
  • Biomaterials Science

Background:

  • Orbital fracture repair often utilizes implants like Medpor®.
  • While generally successful, implants can elicit adverse tissue reactions.
  • Inferior rectus myositis is a rare complication following orbital implant placement.