Clinical Evaluation of a Combined Deep Learning-Reconstructed Readout-Segmented Echo-Planar Imaging and
Jung Min Choi1, Soyeoun Lim1, Eun Jung Choi2,3
1Department of Radiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan 44033, Republic of Korea.
Abstract:
Objectives: This study evaluates the protocol-level image quality and quantitative diffusion metrics of a clinically implemented deep-learning-reconstructed readout-segmented echo-planar imaging protocol with water-excitation spectral fat saturation (DL-rs-EPI with WEXfs) compared with conventional rs-EPI using spectral attenuated inversion recovery (SPAIR) at 3 T. Methods: Overall, 80 patients underwent breast magnetic resonance imaging (MRI) with both conventional rs-EPI with SPAIR and DL-rs-EPI with WEXfs protocols (b-values: 0, 800, and 1200 s/mm2). ROI-based relative image-quality metrics, including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and lesion contrast, were assessed at b = 800 and b = 1200 s/mm2; apparent diffusion coefficient (ADC) values were calculated using multi-b-value data. Fat suppression, background diffusion signal, lesion conspicuity, and artifact severity were qualitatively evaluated. A temperature-controlled diffusion phantom (CaliberMRI) was scanned; ADC values were compared with reference values at 24 °C. Results: DL-rs-EPI with WEXfs demonstrated higher ROI-based relative SNR estimates (b800: 5.79 vs. 5.28; b1200: 5.41 vs. 4.94; p < 0.001) and CNR estimates (b800: 3.35 vs. 3.12, p = 0.024; b1200: 3.67 vs. 3.37, p = 0.001), with unchanged lesion contrast. Tumor ADC values were comparable between protocols, whereas normal fibroglandular tissue ADC values were slightly higher, and ADC contrast increased with DL-rs-EPI with WEXfs. Phantom ADC values from both protocols closely matched reference values at 24 °C, without significant differences. DL-rs-EPI with WEXfs demonstrated more homogeneous fat suppression and reduced background diffusion signal, with comparable lesion conspicuity and artifact severity. Conclusions: The combined DL-rs-EPI with WEXfs protocol demonstrated improved qualitative and relative quantitative image quality while preserving tumor ADC measurements. As a protocol-level evaluation, these composite improvements support its clinical feasibility for high-quality breast DWI without implying the isolated effect of DL reconstruction alone.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...