Source-Only Transportability of Engineered ECG Features for Healthy-Versus-Myocardial Infarction Classification
Fatih Aydın1, Sefer Usta2, Ezgi Kalaycıoğlu2
1Department of Electrical and Electronics Engineering, Karadeniz Technical University, 61080 Trabzon, Türkiye.
None:
Background/Objectives: Electrocardiogram (ECG)-based myocardial infarction (MI) classifiers may achieve high internal validation performance but show reduced performance when applied to data from another source. The task is a controlled binary healthy-versus-MI benchmark and is not intended to represent real-world chest-pain triage or autonomous clinical deployment. This study evaluated the source-only transportability of engineered 12-lead ECG feature families for binary healthy-versus-MI classification across a cardiologist-annotated hospital dataset and PTB-XL. Methods: The hospital dataset contained 1749 usable recordings from 1434 patients after excluding 206 broken-data records, with 1550 Healthy and 199 MI recordings. The matched PTB-XL binary subset contained 14,982 recordings from 13,436 patients, with 9513 Healthy and 5469 MI recordings. Eleven engineered feature families and five classifier families were compared under preprocessing, patient-aware splitting, source-validation hyperparameter and threshold selection, and bootstrap uncertainty estimation. The reported leading rows are the highest observed configurations in a prespecified benchmark grid, not locked clinical models. Results: Internal performance was higher than strict source-only transfer performance. In the hospital dataset, fiducial interval descriptors with Extra Trees reached balanced accuracy 0.775 and receiver operating characteristic area under the curve (ROC-AUC) 0.855. In PTB-XL, a broad hybrid feature bank with ST-segment information and XGBoost reached a balanced accuracy of 0.898 and ROC-AUC of 0.965. Strict source-only transfer was weaker and asymmetric: the highest observed balanced accuracy was 0.580 for hospital-to-PTB-XL transfer and 0.632 for PTB-XL-to-hospital transfer. Ranking transportability and operating-threshold transportability diverged, most notably for hospital-to-PTB-XL transfer, where ROC-AUC was 0.774 but sensitivity at the source-selected threshold was only 0.164. A secondary target-threshold analysis improved balanced accuracy to 0.682 and 0.640, respectively, but this used target labels only to re-select the operating threshold and was not a strict source-only result. Conclusions: The findings indicate a transportability gap: PTB-XL-to-hospital transfer was more balanced than hospital-to-PTB-XL transfer, but neither direction achieved performance comparable to internal validation. The source-only operating-point results are not acceptable for clinical MI screening or decision support without additional calibration, target-setting validation, and prospective assessment.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...