Bolt Preload Identification Method Based on Multi-Frequency Guided Wave Reconstruction and Spectral Centroid Fusion
Zhangsheng Sun1, Zhen Jin1, Zhengwu Yi2
1School of Electronic Information and Electrical Engineering, Yangtze University, Jingzhou 434023, China.
Abstract:
Bolted joints are critical load-transfer components in bridges, wind turbines, aerospace systems, mechanical equipment, and offshore platforms, where preload loss can degrade stiffness, accelerate fatigue, and compromise safety. For structural health monitoring, early monitoring of preload reduction before marked loosening is essential, yet existing ultrasonic guided wave indicators remain affected by frequency dependence, non-monotonic responses, amplitude drift, and environmental disturbances. This study proposes an early-warning-oriented preload identification method that combines broadband excitation, multi-frequency narrowband reconstruction, spectral centroid extraction, optimized weighted fusion, and fixed SC-domain linear calibration from one reference loading group. Using a 20-250 kHz Chirp response, 14 narrowband signals from 50 to 180 kHz were reconstructed for an M20 single-bolt specimen tested over 50-90 N·m. The fused spectral centroid index exhibited a stable, monotonic, and approximately linear relationship with preload. When fixed weights and calibration coefficients were transferred to held-out repeated-loading groups, all Pearson correlation coefficients exceeded 0.99. Feature-level robustness tests showed that the arithmetic mean of the spectral centroid reduced temperature-induced Range% by 98.42-99.08% and RSD by 98.89-99.31% relative to energy-based features. This work provides an interpretable multi-frequency spectral descriptor and a calibration transfer framework for repeatable early warning of preload loss in a controlled single-bolt configuration.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
03:58Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
Published on: January 17, 2025
Related Concept Videos
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Tandem Mass Spectrometry
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...